Analyze Publications Database

3,803 (and counting) Analyze-related scholarly articles

Most Recent Publications

Renal ischemia alters expression of mitochondria-related genes and impairs mitochondrial structure and function in swine scattered tubular-like cells

Rahele A Farahani et al. Renal ischemia alters expression of mitochondria-related genes and impairs mitochondrial structure and function in swine scattered tubular-like cells. Renal Physiology. Publication Date May 28, 2020 How Analyze was Used “Medullary hemodynamics (were evaluated) using Analyze software as previously described.” Keywords Renovascular disease, Renal artery stenosis, Mitochondria, Scattered tubular cells Author…

Distance Mapping of the Foot and Ankle Joints using Weightbearing CT: The Cavovarus Configuration

François Lintz et al. Distance Mapping of the Foot and Ankle Joints using Weightbearing CT: The Cavovarus Configuration. Foot and Ankle Surgery. Publication Date May 26, 2020 How Analyze was Used “A 3-step process was used to prepare the datasets for distance mapping. It consisted of segmentation using (AnalyzeDirect™, Overland Park, Kansas)…of the articulating bones….

Automatization and improvement of μCT analysis for murine lung disease models using a deep learning approach

Gerald Birk et al. Automatization and improvement of μCT analysis for murine lung disease models using a deep learning approach. Respiratory Research. Publication Date May 24, 2020 How Analyze was Used “Threshold-based, semi-automated segmentation and generation of lung densitometric data were done using Analyze 12 (AnalyzeDirect, Inc.).” Keywords Lung disease models, Deep learning, Micro-CT, Computational…

An “all-in-one” scaffold targeting macrophages to direct endogenous bone repair in situ

Yiming Niu et al. An “all-in-one” scaffold targeting macrophages to direct endogenous bone repair in situ. Acta Biomaterialia. Publication Date May 21, 2020 How Analyze was Used “Image segmentation was conducted using a volume-editing tool, and volumes were quantified using the region of interest (ROI) module within the software package (AnalyzeDirect, Overland Park, KS, USA).”…

Adjunctive mesenchymal stem/stromal cells augment microvascular function in poststenotic kidneys treated with low‐energy shockwave therapy

Xiao‐Jun Chen et al. Adjunctive mesenchymal stem/stromal cells augment microvascular function in poststenotic kidneys treated with low‐energy shockwave therapy. The Journal of Cellular Physiology. Publication Date May 19, 2020 How Analyze was Used “MDCT images were reconstructed and displayed with the Analyze® software package. For data analysis, the aorta, renal cortex, and medulla were all…

Placental vascular tree characterization based on ex-vivo MRI with a potential application for placental insufficiency assessment

Daphna Link et al. Placental vascular tree characterization based on ex-vivo MRI with a potential application for placental insufficiency assessment. Placenta. Publication Date May 19, 2020 How Analyze was Used “Imaging data analysis for placental characterization. For placental characterization, a computer-based semi-automatic analysis method was developed using commercial tools (AnalyzeDirect software) as well as in-house…

3D printed porous PEEK created via fused filament fabrication for osteoconductive orthopaedic surfaces

H. Spece et al. 3D printed porous PEEK created via fused filament fabrication for osteoconductive orthopaedic surfaces. Journal of the Mechanical Behavior of Biomedical Materials. Publication Date May 11, 2020 How Analyze was Used “The structures were then rendered in Analyze 12.0 software (AnalyzeDirect, Overland Park, KS) to determine the interconnectivity of the internal pore…

The slice score: A novel scale measuring intraventricular hemorrhage severity and predicting poor outcome following intracerebral hemorrhage

Rui Li et al. The slice score: A novel scale measuring intraventricular hemorrhage severity and predicting poor outcome following intracerebral hemorrhage. Clinical Neurology and Neurosurgery. Publication Date May 11, 2020 How Analyze was Used “To acquire a reliable volumetric data, all ICH and IVH volumes were calculated using computer-assisted segmentation with Analyze 11.0 software (AnalyzeDirect,…

Effect of Balloon Guide Catheter Utilization on the Incidence of Sub-angiographic Peripheral Emboli on High-Resolution DWI After Thrombectomy: A Prospective Observational Study

Michael Hinrich Schönfeld et al. Effect of Balloon Guide Catheter Utilization on the Incidence of Sub-angiographic Peripheral Emboli on High-Resolution DWI After Thrombectomy: A Prospective Observational Study. Frontiers in Neurology. Publication Date May 8, 2020 How Analyze was Used “All DWI lesions were semi-automatically segmented using seed growing algorithms provided by the Analyze 11.0 software…

Symptom relief and quality of life after combined partial hepatectomy and cyst fenestration in highly symptomatic polycystic liver disease

Lucas H.P. Bernts et al. Symptom relief and quality of life after combined partial hepatectomy and cyst fenestration in highly symptomatic polycystic liver disease. Surgery. Publication Date May 8, 2020 How Analyze was Used “A blinded investigator (ME) measured total liver volume, presurgery and postsurgery using Analyze software. In patients with polycystic kidney disease, we…