Tag Archives: Reproducibility of Results

How the cervix shortens: an anatomic study using 3-dimensional transperineal sonography and image registration in singletons and twins

Parikh R, Patel A, Stack T, Socrate S, House M. How the cervix shortens: an anatomic study using 3-dimensional transperineal sonography and image registration in singletons and twins. J Ultrasound Med. September 2011;30(9):1197-1204. Full Text – Open Access Publication Date September 2011 How Analyze was Used “Using ImageJ … the 30 sagittal images were converted…

Suicidal behavior is associated with reduced corpus callosum area

Cyprien F, Courtet P, Malafosse A, Maller J, Meslin C, Bonafe A, Le Bars E, de Champfleur NM, Ritchie K, Artero S. Suicidal behavior is associated with reduced corpus callosum area. Biol Psychiatry. August 2011;70(4):320-326. Publication Date August 2011 How Analyze was Used “The CC outline was manually traced on the midline sagittal slice of…

CT cerebral blood flow maps optimally correlate with admission diffusion-weighted imaging in acute stroke but thresholds vary by postprocessing platform

Kamalian S, Kamalian S, Maas MB, Goldmacher GV, Payabvash S, Akbar A, Schaefer PW, Furie KL, Gonzalez RG, Lev MH. CT cerebral blood flow maps optimally correlate with admission diffusion-weighted imaging in acute stroke but thresholds vary by postprocessing platform. Stroke. July 2011;42(7):1923-1928. Full Text – Open Access Publication Date July 2011 How Analyze was…

A novel method for computerized measurement of episcleral venous pressure in humans

Sit AJ, Ekdawi NS, Malihi M, McLaren JW. A novel method for computerized measurement of episcleral venous pressure in humans. Exp Eye Res. June 2011;92(6):537-544. Publication Date June 2011 How Analyze was Used “To assist with manual measurement of vein width, we developed custom software that used image processing methods to determine stages of vessel…

On the use of a spin-echo based double inversion recovery acquisition for the measurement of cortical brain thickness

Nam Y, Kim EY, Kim DH. On the use of a spin-echo based double inversion recovery acquisition for the measurement of cortical brain thickness. J Magn Reson Imaging. May 2011;33(5):1218-1223. Publication Date May 2011 How Analyze was Used “[The] segmentation step was done using the Analyze 9.0 software (AnalyzeDirect, inc). Then, the signal intensities of…

Frequency of adequate contrast opacification of the major intracranial venous structures with CT angiography in the setting of intracerebral hemorrhage: comparison of 16- and 64-section CT angiography techniques

Delgado Almandoz JE, Su HS, Schaefer PW, Goldstein JN, Pomerantz SR, Lev MH, Gonzalez RG, Romero JM. Frequency of adequate contrast opacification of the major intracranial venous structures with CT angiography in the setting of intracerebral hemorrhage: comparison of 16- and 64-section CT angiography techniques. AJNR Am J Neuroradiol. May 2011;32(5):839-845. Full Text – Open…

Detection of amyloid plaques targeted by USPIO-Aß1-42 in Alzheimer’s disease transgenic mice using magnetic resonance microimaging

Yang J, Wadghiri YZ, Hoang DM, Tsui W, Sun Y, Chung E, Li Y, Wang A, de Leon M, Wisniewski T. Detection of amyloid plaques targeted by USPIO-Aß1-42 in Alzheimer’s disease transgenic mice using magnetic resonance microimaging. Neuroimage. April 2011;55(4):1600-1609. Full Text – Open Access Publication Date April 2011 How Analyze was Used “The advantage…

Relationship between sodium intensity and perfusion deficits in acute ischemic stroke

Tsang A, Stobbe RW, Asdaghi N, Hussain MS, Bhagat YA, Beaulieu C, Emery D, Butcher KS. Relationship between sodium intensity and perfusion deficits in acute ischemic stroke. J Magn Reson Imaging. January 2011;33(1):41-47. Publication Date January 2011 How Analyze was Used “Regional PWI and DWI image analysis was performed using the Analyze software package.” Keywords…

Imaging dopamine receptors in humans with [11C]-(+)-PHNO: dissection of D3 signal and anatomy

Tziortzi AC, Searle GE, Tzimopoulou S, Salinas C, Beaver JD, Jenkinson M, Laruelle M, Rabiner EA, Gunn RN. Imaging dopamine receptors in humans with [11C]-(+)-PHNO: dissection of D3 signal and anatomy. Neuroimage. January 2011;54(1):264-277. Publication Date January 2011 How Analyze was Used “All ROIs except SN [substantia nigra] were defined on the high-resolution MR image…

Reliability of two techniques for assessing cerebral iron deposits with structural magnetic resonance imaging

Valdés Hernández MC, Jeong TH, Murray C, Bastin ME, Chappell FM, Deary IJ, Wardlaw JM. Reliability of two techniques for assessing cerebral iron deposits with structural magnetic resonance imaging. J Magn Reson Imaging. January 2011;33(1):54-61. Publication Date January 2011 How Analyze was Used “A brain mask was then obtained from the T2*W data using the…