Tag Archives: Quality Control

Optimization of chest radiographic imaging parameters: a comparison of image quality and entrance skin dose for digital chest radiography systems

Sun Z, Lin C, Tyan Y, Ng KH. Optimization of chest radiographic imaging parameters: a comparison of image quality and entrance skin dose for digital chest radiography systems. Clin Imaging. July 2012;36(4):279-286. Publication Date July 2012 How Analyze was Used “All of the original chest radiographic images were saved in DICOM (digital imaging and communication…

Validation and quantification of [18F]altanserin binding in the rat brain using blood input and reference tissue modeling

Riss PJ, Hong YT, Williamson D, Caprioli D, Sitnikov S, Ferrari V, Sawiak SJ, Baron JC, Dalley JW, Fryer TD, Aigbirhio FI. Validation and quantification of [18F]altanserin binding in the rat brain using blood input and reference tissue modeling. J Cereb Blood Flow Metab. December 2011;31(12):2334-2342. Full Text – Open Access Publication Date December 2011…

MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning

Blackall JM, Ahmad S, Miquel ME, McClelland JR, Landau DB, Hawkes DJ. MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning. Phys Med Biol. September 2006;51(17):4147-4169. Publication Date September 2006 How Analyze was Used “Prior to registration of the images, the lung was segmented from the reference volume using the…

A faster method for 3D/2D medical image registration–a simulation study

Birkfellner W, Wirth J, Burgstaller W, Baumann B, Staedele H, Hammer B, Gellrich NC, Jacob AL, Regazzoni P, Messmer P. A faster method for 3D/2D medical image registration–a simulation study. Phys Med Biol. August 2003;48(16):2665-2679. Publication Date August 2003 How Analyze was Used “Three clinical CT-scans of a pelvis, a midface and a tibia were…

Diffusion tensor fiber tracking of human brain connectivity: aquisition methods, reliability analysis and biological results

Lori NF, Akbudak E, Shimony JS, Cull TS, Snyder AZ, Guillory RK, Conturo TE. Diffusion tensor fiber tracking of human brain connectivity: aquisition methods, reliability analysis and biological results. NMR Biomed. November 2002;15(7-8):494-515. Full Text – Open Access Publication Date November 2002 How Analyze was Used “The 2D anatomical overlays are viewed using Analyze AVW®…

Effectiveness and relevance of MR acceptance testing: results of an 8 year audit

McRobbie DW, Quest RA. Effectiveness and relevance of MR acceptance testing: results of an 8 year audit. Br J Radiol. June 2002;75(894):523-531. Publication Date June 2002 How Analyze was Used “Where possible images were evaluated by transferring image data by CD, Magneto-Optical Disk or network to a Sun workstation running Analyze ™ software (AnalyzeDirect Inc.,…

Volumetric measurement of renal cysts and parenchyma using MRI: phantoms and patients with polycystic kidney disease

Bae KT, Commean PK, Lee J. Volumetric measurement of renal cysts and parenchyma using MRI: phantoms and patients with polycystic kidney disease. J Comput Assist Tomogr. July 2000;24(4):614-619. Publication Date July 2000 How Analyze was Used “The stereology method implemented in the Analyze software system … was applied to T2-weighted MR images from the phantoms…