Annalisa Bettini et al. CT-Visible Microspheres Enable Whole-body In Vivo Tracking of Injectable Tissue Engineering Scaffolds Advanced Healthcare Materials Publication Date April 28, 2024 How Analyze was Used “Image segmentation was performed using the Analyze 12.0 software (AnalyzeDirect) using a combination of the ‘Semi-automatic’ and ‘Manual Technique’ settings. A 3D rendering of the implanted microspheres…
Lemoine S, Papillard M, Belloi A, Rognant N, Fouque D, Laville M, Rouviere O, Juillard L. Renal perfusion: noninvasive measurement with multidetector CT versus fluorescent microspheres in a pig model. Radiology. August 2011;260(2):414-420. Full Text – Open Access Publication Date August 2011 How Analyze was Used “Regions of interest (ROIs) were traced on four of…
Malyar NM, Lerman LO, Gössl M, Beighley PE, Ritman EL. Relationship between surface area of nonperfused myocardium and extravascular extraction of contrast agent following coronary microembolization. Am J Physiol Regul Integr Comp Physiol. August 2011;301(2):R430-437. Full Text – Open Access Publication Date August 2011 How Analyze was Used “Images of EBCT and micro-CT were analyzed…
Kempen DHR, Lu L, Hefferan TE, Creemers LB, Maran A, Classic KL, Dhert WJA, Yaszemski MJ. Retention of in vitro and in vivo BMP-2 bioactivities in sustained delivery vehicles for bone tissue engineering. Biomaterials. August 2008;29(22):3245-3252. Full Text – Open Access Publication Date August 2008 How Analyze was Used “Image analysis was performed using the…
Schindl MJ, Millar AM, Redhead DN, Fearon KCH, Ross JA, Dejong CHC, Garden OJ, Wigmore SJ. The adaptive response of the reticuloendothelial system to major liver resection in humans. Ann Surg. April 2006;243(4):507-514. Full Text – Open Access Publication Date April 2006 How Analyze was Used “Liver volumetry was performed using a spiral multislice CT…
Savai R, Wolf JC, Greschus S, Eul BG, Schermuly RT, Hänze J, Voswinckel R, Langheinrich AC, Grimminger F, Traupe H, Seeger W, Rose F. Analysis of tumor vessel supply in Lewis lung carcinoma in mice by fluorescent microsphere distribution and imaging with micro- and flat-panel computed tomography. Am J Pathol. October 2005;167(4):937-946. Full Text –…
Hoffmann U, Millea R, Enzweiler C, Ferencik M, Gulick S, Titus J, Achenbach S, Kwait D, Sosnovik D, Brady TJ. Acute myocardial infarction: contrast-enhanced multi-detector row CT in a porcine model. Radiology. June 2004;231(3):697-701. Full Text – Open Access Publication Date June 2004 How Analyze was Used “Images were loaded into software (Analyze 3.1 …)….
Gössl M, Malyar NM, Rosol M, Beighley PE, Ritman EL. Impact of coronary vasa vasorum functional structure on coronary vessel wall perfusion distribution. Am J Physiol Heart Circ Physiol. November 2003;285(5):H2019-2026. Full Text – Open Access Publication Date November 2003 How Analyze was Used “The resulting 3-D images were displayed using image analysis software (Analyze…
Möhlenkamp S, Beighley PE, Pfeifer EA, Behrenbeck TR, Sheedy PF, 2nd, Ritman EL. Intramyocardial blood volume, perfusion and transit time in response to embolization of different sized microvessels. Cardiovasc Res. March 2003;57(3):843-852. Full Text – Open Access Publication Date March 2003 How Analyze was Used “Images were evaluated using an image analysis software package (ANALYZE).”…
Eusemann CD, Mohlenkamp S, Ritman EL, Robb RA. 3D quantitative visualization of altered LV wall thickening dynamics caused by coronary microembolization. Paper presented at: Medical Imaging 2001: Physiology and Function from Multidimensional Images, February 2001; San Diego, CA, US. Publication Date February 2001 How Analyze was Used “Segmentations of individual 2-D slices of cardiac image…