Hoad CL, Fulford J, Raine-Fenning NJ, Campbell BK, Johnson IR, Gowland PA. In vivo perfusion, T1, and T2 measurements in the female pelvis during the normal menstrual cycle: a feasibility study. J Magn Reson Imaging. December 2006;24(6):1350-1356.
Publication Date
December 2006
How Analyze was Used
“For T 1 and perfusion, ROIs were drawn using Analyze … on the short inversion time images as these showed the clearest distinction between tissue types.”
Keywords
Adult
Blood Flow Velocity/physiology
Feasibility Studies
Female
Humans
Image Interpretation, Computer-Assisted/methods
Magnetic Resonance Imaging/methods
Menstrual Cycle/physiology
Pelvis/anatomy & histology/blood supply
Perfusion/methods
Reproducibility of Results
Sensitivity and Specificity
Uterus/blood supply/physiology
Author Affiliation(s)
Sir Peter Mansfield Magnetic Resonance Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK. (CLH, JF, PAG)
School of Human Development, University of Nottingham, Nottingham, UK. (NJR-F, BKC, IRJ)
ID# 1957
Tags: Adult, Blood Flow Velocity/physiology, Computer-Assisted Image Interpretation/methods, Feasibility Studies, Female, Humans, Magnetic Resonance Imaging/methods, Menstrual Cycle/physiology, Pelvis/anatomy & histology/blood supply, Perfusion/methods, Reproducibility of Results, Sensitivity and Specificity, Uterus/blood supply/physiology