Tag Archives: Sensitivity and Specificity

Virtual intravascular endoscopy visualization of calcified coronary plaques: a novel approach of identifying plaque features for more accurate assessment of coronary lumen stenosis

Xu L, Sun Z. Virtual intravascular endoscopy visualization of calcified coronary plaques: a novel approach of identifying plaque features for more accurate assessment of coronary lumen stenosis. Medicine (Baltimore). May 2015;94(17):e805. Full Text – Open Access Publication Date May 2015 How Analyze was Used “CT volume data were converted from original DICOM (digital imaging and…

Semiautomatic segmentation and follow-up of multicomponent low-grade tumors in longitudinal brain MRI studies

Weizman L, Sira LB, Joskowicz L, Rubin DL, Yeom KW, Constantini S, Shofty B, Bashat DB. Semiautomatic segmentation and follow-up of multicomponent low-grade tumors in longitudinal brain MRI studies. Med Phys. May 2014;41(5):052303. Publication Date May 2014 How Analyze was Used “One radiologist from each institution manually produced segmentations for the scans acquired at his/her…

T1-weighted axial visual rating scale for an assessment of medial temporal atrophy in Alzheimer’s disease

Kim GH, Kim JE, Choi KG, Lim SM, Lee JM, Na DL, Jeong JH. T1-weighted axial visual rating scale for an assessment of medial temporal atrophy in Alzheimer’s disease. J Alzheimers Dis. March 2014;41(1):169-178. Full Text – Open Access Publication Date March 2014 How Analyze was Used “Manual tracing of the hippocampus on T1W-coronal MR…

Transverse ultrasound assessment of median nerve deformation and displacement in the human carpal tunnel during wrist movements

Wang Y, Zhao C, Passe SM, Filius A, Thoreson AR, An KN, Amadio PC. Transverse ultrasound assessment of median nerve deformation and displacement in the human carpal tunnel during wrist movements. Ultrasound Med Biol. January 2014;40(1):53-61. Full Text – Open Access Publication Date January 2014 How Analyze was Used “Each subject was imaged while sitting…

Intracranial-derived atherosclerosis assessment: an in vitro comparison between virtual histology by intravascular ultrasonography, 7T MRI, and histopathologic findings

Majidi S, Sein J, Watanabe M, Hassan AE, Van de Moortele PF, Suri MFK, Clark HB, Qureshi AI. Intracranial-derived atherosclerosis assessment: an in vitro comparison between virtual histology by intravascular ultrasonography, 7T MRI, and histopathologic findings. AJNR Am J Neuroradiol. December 2013;34(12):2259-2264. Publication Date December 2013 How Analyze was Used “Histology slides were photographed under…

Normal-appearing white matter permeability distinguishes poor cognitive performance in processing speed and working memory

Eilaghi A, Kassner A, Sitartchouk I, Francis PL, Jakubovic R, Feinstein A, Aviv RI. Normal-appearing white matter permeability distinguishes poor cognitive performance in processing speed and working memory. AJNR Am J Neuroradiol. November 2013;34(11):2119-2124. Full Text – Open Access Publication Date November 2013 How Analyze was Used “Segmented regions were imported into Analyze 8.0 (Analyze…

Quantification of opioid receptor availability following spontaneous epileptic seizures: correction of [11C]diprenorphine PET data for the partial-volume effect

McGinnity CJ, Shidahara M, Feldmann M, Keihaninejad S, RiaƱo Barros DA, Gousias IS, Duncan JS, Brooks DJ, Heckemann RA, Turkheimer FE, Hammers A, Koepp MJ. Quantification of opioid receptor availability following spontaneous epileptic seizures: correction of [11C]diprenorphine PET data for the partial-volume effect. Neuroimage. October 2013;79:72-80. Publication Date October 2013 How Analyze was Used “First,…

Quantification of cervical spine muscle fat: a comparison between T1-weighted and multi-echo gradient echo imaging using a variable projection algorithm (VARPRO)

Elliott JM, Walton DM, Rademaker A, Parrish TB. Quantification of cervical spine muscle fat: a comparison between T1-weighted and multi-echo gradient echo imaging using a variable projection algorithm (VARPRO). BMC Med Imaging. September 2013;13:30. Full Text – Open Access Publication Date September 2013 How Analyze was Used “This established measure of relative fat within the…

18F-ICMT-11, a caspase-3-specific PET tracer for apoptosis: biodistribution and radiation dosimetry

Challapalli A, Kenny LM, Hallett WA, Kozlowski K, Tomasi G, Gudi M, Al-Nahhas A, Coombes RC, Aboagye EO. 18F-ICMT-11, a caspase-3-specific PET tracer for apoptosis: biodistribution and radiation dosimetry. J Nucl Med. September 2013;54(9):1551-1556. Full Text – Open Access Publication Date September 2013 How Analyze was Used “To avoid tissue inhomogeneity, particularly near organ boundaries,…

Perfusion MR predicts outcome in high-risk transient ischemic attack/minor stroke: a derivation-validation study

Asdaghi N, Hill MD, Coulter JI, Butcher KS, Modi J, Qazi A, Goyal M, Demchuk AM, Coutts SB. Perfusion MR predicts outcome in high-risk transient ischemic attack/minor stroke: a derivation-validation study. Stroke. September 2013;44(9):2486-2492. Full Text – Open Access Publication Date September 2013 How Analyze was Used “Maps of Tmax were imported into the Analyze…