Tag Archives: Medical Imaging

Silicone phantoms fabricated with multi-material extrusion 3D printing technology mimicking imaging properties of soft tissues in CT

Sepideh Hatamikia et al. Silicone phantoms fabricated with multi-material extrusion 3D printing technology mimicking imaging properties of soft tissues in CT ArXiv. Publication Date December 6, 2022 How Analyze was Used “In case of the anatomical phantom the obtained HU values were compared with those of the original human CT data. Analyze 12.0 toolkit (AnalyzeDirect,…

Realistic 3D printed imaging tumor phantoms for validation of image processing algorithms

Sepideh Hatamikia et al. Realistic 3D printed imaging tumor phantoms for validation of image processing algorithms ArXiv. Publication Date November 27, 2022 How Analyze was Used “We used the Analyze 12.0 toolkit (AnalyzeDirect, Overland Park, United States) in order to measure the HU values from the CT scan related to patients, printed cylinders and printed…

Radiomics analysis of MRI for predicting molecular subtypes of breast cancer in young women

Qinmei Li et al. Radiomics analysis of MRI for predicting molecular subtypes of breast cancer in young women. Medical Imaging. Publication Date March 14, 2019 How Analyze was Used “After the acquisition of images, all T2-weighted images were loaded into ImageJ to form a High Dynamic Range Imaging (HDR imaging), then HDR imaging were input…

Dimensional accuracy of 3D printed vertebra

Ogden K, Ordway N, Diallo D, Tillapaugh-Fay G, Asian C. Dimensional accuracy of 3D printed vertebra. Paper presented at: SPIE Medical Imaging 2014: Image-Guided Procedures, Robotic Interventions, and Modeling, 903610; March 2014; San Diego, CA, US. Publication Date March 2014 How Analyze was Used “The CT scan was downloaded to a local computer for processing…

Quantification of porcine vocal fold geometry in three dimensions

Stevens KA, Jette M, Thibeault S, Thomson SL. Quantification of porcine vocal fold geometry in three dimensions. Paper presented at: International Congress of Acoustics; June 2013; Montreal, Canada. Publication Date June 2013 How Analyze was Used “The microCT data were imported into Analyzet 8.1, a commercial biomedical imaging and analysis software, and resampled with half…

3D-3D registration of partial capitate bones using spin-images

Breighner RE, Holmes DR, Leng S, An K-N, McCollough CH, Zhao KD. 3D-3D registration of partial capitate bones using spin-images. Paper presented at: SPIE Medical Imaging 2013: Image-Guided Procedures, Robotic Interventions, and Modeling, February 2013; Lake Buena Vista, FL. Publication Date February 2013 How Analyze was Used “The segmented capitates were meshed using an adaptive…

Automated “prostate‐only” registration of CT/MR images for post‐implant dosimetric assessment of permanent seed brachytherapy

Sloboda R. Automated “prostate‐only” registration of CT/MR images for post‐implant dosimetric assessment of permanent seed brachytherapy. Med Phys. June 2007;34(6):2421-2421. Publication Date June 2007 How Analyze was Used “NMI‐based registration was performed using the MatchLab module in the Analyze 7.0 software package, which affords control of an extensive range of registration parameters. These parameters were…

Comparison between two small animal imaging ct devices used for quantifying lung damage in mice in vivo

Cavanaugh D, Gladish G, Travis E, White R, Cody D. Comparison between two small animal imaging ct devices used for quantifying lung damage in mice in vivo. Med Phys. June 2005;32(6):2134-2134. Publication Date June 2005 How Analyze was Used “Lung volumes at each time point were calculated using Analyze 5.0 for both the micro‐CT and…