Tag Archives: Image Enhancement/methods

Quantification of opioid receptor availability following spontaneous epileptic seizures: correction of [11C]diprenorphine PET data for the partial-volume effect

McGinnity CJ, Shidahara M, Feldmann M, Keihaninejad S, Riaño Barros DA, Gousias IS, Duncan JS, Brooks DJ, Heckemann RA, Turkheimer FE, Hammers A, Koepp MJ. Quantification of opioid receptor availability following spontaneous epileptic seizures: correction of [11C]diprenorphine PET data for the partial-volume effect. Neuroimage. October 2013;79:72-80. Publication Date October 2013 How Analyze was Used “First,…

Quantification of cervical spine muscle fat: a comparison between T1-weighted and multi-echo gradient echo imaging using a variable projection algorithm (VARPRO)

Elliott JM, Walton DM, Rademaker A, Parrish TB. Quantification of cervical spine muscle fat: a comparison between T1-weighted and multi-echo gradient echo imaging using a variable projection algorithm (VARPRO). BMC Med Imaging. September 2013;13:30. Full Text – Open Access Publication Date September 2013 How Analyze was Used “This established measure of relative fat within the…

FLAIR lesion segmentation: application in patients with brain tumors and acute ischemic stroke

Artzi M, Aizenstein O, Jonas-Kimchi T, Myers V, Hallevi H, Ben Bashat D. FLAIR lesion segmentation: application in patients with brain tumors and acute ischemic stroke. Eur J Radiol. September 2013;82(9):1512-1518. Publication Date September 2013 How Analyze was Used “Manual delineation was performed using commercial software [Analyze, version 9.0] (AnalyzeDirect).” Keywords Acute Disease Algorithms Artificial…

Mouse brain fixation to preserve in vivo manganese enhancement for ex vivo manganese-enhanced MRI

Liu Y, Sajja BR, Gendelman HE, Boska MD. Mouse brain fixation to preserve In vivo manganese enhancement for ex vivo manganese-enhanced MRI. J Magn Reson Imaging. August 2013;38(2):482-487. Full Text – Open Access Publication Date August 2013 How Analyze was Used “Based on Paxinos mouse brain atlas [Paxinos and Franklin 2001], brain structures including cerebral cortex…

Towards automated detection of depression from brain structural magnetic resonance images

Kipli K, Kouzani AZ, Williams LJ. Towards automated detection of depression from brain structural magnetic resonance images. Neuroradiology. May 2013;55(5):567-584. Publication Date May 2013 How Analyze was Used “Semiautomated tools, i.e., BRAINS and Analyze, are popular for specific brain regions segmentation and traditional volume measurement [Kipli et al. 2012].” Keywords Algorithms Artificial Intelligence Brain/pathology Depression/diagnosis…

Prediction of brain MR scans in longitudinal tumor follow-up studies

Weizman L, Ben-Sira L, Joskowicz L, Aizenstein O, Shofty B, Constantini S, Ben-Bashat D. Prediction of brain MR scans in longitudinal tumor follow-up studies. Med Image Comput Comput Assist Interv. October 2012;15(Pt 2):179-187. Publication Date October 2012 How Analyze was Used “An expert radiologist manually produced tumor segmentations for the current, predicted, and the actual…

Numerical simulation of SAR induced around Co-Cr-Mo hip prostheses in situ exposed to RF fields associated with 1.5 and 3 T MRI body coils

Powell J, Papadaki A, Hand J, Hart A, McRobbie D. Numerical simulation of SAR induced around Co-Cr-Mo hip prostheses in situ exposed to RF fields associated with 1.5 and 3 T MRI body coils. Magn Reson Med. September 2012;68(3):960-968. Full Text – Open Access Publication Date September 2012 How Analyze was Used “A CT (Siemens…

Reproducibility and repeatability of quantitative sodium magnetic resonance imaging in vivo in articular cartilage at 3 T and 7 T

Madelin G, Babb JS, Xia D, Chang G, Jerschow A, Regatte RR. Reproducibility and repeatability of quantitative sodium magnetic resonance imaging in vivo in articular cartilage at 3 T and 7 T. Magn Reson Med. September 2012;68(3):841-849. Full Text – Open Access Publication Date September 2012 How Analyze was Used “For each volunteer, all 16…

Speckle-tracking sonographic assessment of longitudinal motion of the flexor tendon and subsynovial tissue in carpal tunnel syndrome

van Doesburg MH, Yoshii Y, Henderson J, Villarraga HR, Moran SL, Amadio PC. Speckle-tracking sonographic assessment of longitudinal motion of the flexor tendon and subsynovial tissue in carpal tunnel syndrome. J Ultrasound Med. July 2012;31(7):1091-1098. Full Text – Open Access Publication Date July 2012 How Analyze was Used “The intraoperative data were digitized to determine…

Endocardial border detection in cardiac magnetic resonance images using level set method

Ammar M, Mahmoudi S, Chikh MA, Abbou A. Endocardial border detection in cardiac magnetic resonance images using level set method. J Digit Imaging. April 2012;25(2):294-306. Full Text – Open Access Publication Date April 2012 How Analyze was Used “They used a software package that is well established for the post-processing of medical images (Analyze…). The…