Acosta-Cabronero J, Alley S, Williams GB, Pengas G, Nestor PJ. Diffusion tensor metrics as biomarkers in Alzheimer’s disease. PLoS One. November 2012;7(11):e49072. Full Text – Open Access Publication Date November 2012 How Analyze was Used “Each T1-weighted structural volume was affine-registered to its corresponding b0 image, hence enabling the midline corpus callosum to be individually…
Rettmann ME, Gunawan MS, Holmes DR, 3rd, Breen JF, Packer DL, Robb RA. Centerline tracking for quantification of reverse structural remodeling of the pulmonary veins following cardiac ablation therapy. Acad Radiol. November 2012;19(11):1332-1344. Full Text – Open Access Publication Date November 2012 How Analyze was Used “Analyze-AVW technology … was used to analyze some of…
Clark L, Stokes PR, Wu K, Michalczuk R, Benecke A, Watson BJ, Egerton A, Piccini P, Nutt DJ, Bowden-Jones H, Lingford-Hughes AR. Striatal dopamine D2/D3 receptor binding in pathological gambling is correlated with mood-related impulsivity. Neuroimage. October 2012;63(1):40-46. Full Text – Open Access Publication Date October 2012 How Analyze was Used “The deformed striatal atlas…
Yoo AJ, Hu R, Hakimelahi R, Lev MH, Nogueira RG, Hirsch JA, Gonzalez RG, Schaefer PW. CT angiography source images acquired with a fast-acquisition protocol overestimate infarct core on diffusion weighted images in acute ischemic stroke. J Neuroimaging. October 2012;22(4):329-335. Full Text – Open Access Publication Date October 2012 How Analyze was Used “Volume measurements…
Klopfenstein BJ, Kim MS, Krisky CM, Szumowski J, Rooney WD, Purnell JQ. Comparison of 3 T MRI and CT for the measurement of visceral and subcutaneous adipose tissue in humans. Br J Radiol. October 2012;85(1018):e826-830. Full Text – Open Access Publication Date October 2012 How Analyze was Used “Analyze v. 7.0 (AnalyzeDirect, Inc., Overland Park,…
Mok V, Ding D, Fu J, Xiong Y, Chu WW, Wang D, Abrigo JM, Yang J, Wong A, Zhao Q, Guo Q, Hong Z, Wong KS. Transcranial Doppler ultrasound for screening cerebral small vessel disease: a community study. Stroke. October 2012;43(10):2791-2793. Full Text – Open Access Publication Date October 2012 How Analyze was Used “WML…
Uchida H, Suzuki T, Graff-Guerrero A, Mulsant BH, Pollock BG, Arenovich T, Rajji TK, Mamo DC. Therapeutic window for striatal dopamine D2/3 receptor occupancy in older patients with schizophrenia: a pilot PET study. Am J Geriatr Psychiatry. October 2012. Publication Date October 2012 How Analyze was Used “An ROI analysis was completed by one of…
Kumar PV, Alli O, Bjarnason H, Hagler DJ, Sundt TM, Rihal CS. Percutaneous therapeutic approaches to closure of cardiac pseudoaneurysms. Catheter Cardiovasc Interv. October 2012;80(4):687-699. Publication Date October 2012 How Analyze was Used “Three-dimensional imaging with CT with added segmentation analysis using the Analyze visualization software… might be helpful in segmenting the LV pseudoaneurysm and…
Sheard B, Elliott J, Cagnie B, O’Leary S. Evaluating serratus anterior muscle function in neck pain using muscle functional magnetic resonance imaging. J Manipulative Physiol Ther. October 2012;35(8):629-635. Publication Date October 2012 How Analyze was Used “The SA muscle was identified at the level, and the Analyze software (v. 10.0 AnalyzeDirect, Overland Park, KS) was…
Cyarto EV, Lautenschlager NT, Desmond PM, Ames D, Szoeke C, Salvado O, Sharman MJ, Ellis KA, Phal PM, Masters CL, Rowe CC, Martins RN, Cox KL. Protocol for a randomized controlled trial evaluating the effect of physical activity on delaying the progression of white matter changes on MRI in older adults with memory complaints and…