Tag Archives: Computer Simulation

Fenestrated stent graft repair of abdominal aortic aneurysm: hemodynamic analysis of the effect of fenestrated stents on the renal arteries

Sun Z, Chaichana T. Fenestrated stent graft repair of abdominal aortic aneurysm: hemodynamic analysis of the effect of fenestrated stents on the renal arteries. Korean J Radiol. January 2010;11(1):95-106. Full Text – Open Access Publication Date January 2010 How Analyze was Used “For generating 3D realistic AAA models, the CT volume data was postprocessed with…

Acquisition of 3-D arterial geometries and integration with computational fluid dynamic

Hammer S, Jeays A, Allan PL, Hose R, Barber D, Easson WJ, Hoskins PR. Acquisition of 3-D arterial geometries and integration with computational fluid dynamics. Ultrasound Med Biol. December 2009;35(12):2069-2083. Publication Date December 2009 How Analyze was Used “The arterial geometry is extracted from the 3-D dataset. A manual method was used, in which points…

Multi-body simulation of a canine hind limb: model development, experimental validation and calculation of ground reaction forces

Helms G, Behrens BA, Stolorz M, Wefstaedt P, Nolte I. Multi-body simulation of a canine hind limb: model development, experimental validation and calculation of ground reaction forces. Biomed Eng Online. November 2009;8:36. Full Text – Open Access Publication Date November 2009 How Analyze was Used “Based on the different Hounsfield units (HU) of the different…

ABC/2 for rapid clinical estimate of infarct, perfusion, and mismatch volumes

Sims JR, Gharai LR, Schaefer PW, Vangel M, Rosenthal ES, Lev MH, Schwamm LH. ABC/2 for rapid clinical estimate of infarct, perfusion, and mismatch volumes. Neurology. June 2009;72(24):2104-2110. Full Text – Open Access Publication Date June 2009 How Analyze was Used “DWI and MTT lesions volumes were measured by P.W.A. using Analyze 7.0 software (AnalyzeDirect,…

A subject-specific technique for respiratory motion correction in image-guided cardiac catheterisation procedures

King AP, Boubertakh R, Rhode KS, Ma YL, Chinchapatnam P, Gao G, Tangcharoen T, Ginks M, Cooklin M, Gill JS, Hawkes DJ, Razavi RS, Schaeffter T. A subject-specific technique for respiratory motion correction in image-guided cardiac catheterisation procedures. Med Image Anal. June 2009;13(3):419-431. Publication Date June 2009 How Analyze was Used “For both patients and…

Experimental and theoretical characterization of the voltage distribution generated by deep brain stimulation

Miocinovic S, Lempka SF, Russo GS, Maks CB, Butson CR, Sakaie KE, Vitek JL, McIntyre CC. Experimental and theoretical characterization of the voltage distribution generated by deep brain stimulation. Exp Neurol. March 2009;216(1):166-176. Full Text – Open Access Publication Date March 2009 How Analyze was Used “All of the MRI and CT images were coregistered…

A population-average MRI-based atlas collection of the rhesus macaque

McLaren DG, Kosmatka KJ, Oakes TR, Kroenke CD, Kohama SG, Matochik JA, Ingram DK, Johnson SC. A population-average MRI-based atlas collection of the rhesus macaque. Neuroimage. March 2009;45(1):52-59. Full Text – Open Access Publication Date March 2009 How Analyze was Used “3D object maps were manually drawn by trained individuals to delineate brain from non-brain…

The structural implications of a unilateral facial skeletal cleft: a three-dimensional finite element model approach

Zhao L, Herman JE, Patel PK. The structural implications of a unilateral facial skeletal cleft: a three-dimensional finite element model approach. Cleft Palate Craniofac J. March 2008;45(2):121-130. Full Text – Open Access Publication Date March 2008 How Analyze was Used “Using ANALYZE AVW 4.0…, the CT scan data were reformatted and the voxels were resized…

In vitro investigation of biomechanical changes of the hip after Salter pelvic osteotomy

Pfeifer R, Hurschler C, Ostermeier S, Windhagen H, Pressel T. In vitro investigation of biomechanical changes of the hip after Salter pelvic osteotomy. Clin Biomech (Bristol, Avon). March 2008;23(3):299-304. Publication Date March 2008 How Analyze was Used “Continuous 1.5 mm thick slices were used to create a three-dimensional surface reconstruction of the left hemipelvis and…

Patient specific physical anatomy models

Cameron BM, Holmes III DR, Rettmann ME, Robb RA. Patient specific physical anatomy models. In: Westwood JD, ed. Medicine meets virtual reality 16 : parallel, combinatorial, convergent : NextMed by design. Washington, DC: IOS Press; 2008:68-73. Full Text – Open Access Publication Date February 2008 How Analyze was Used “Segmentation is done semi-automatically using our…