Tag Archives: Cardiovascular Models

Comparing Technologies of Additive Manufacturing for the Development of Vascular Models

Johanna Spallek1, Andreas Frölich2, Jan-Hendrik Buhk2, Jens Fiehler2, Dieter Krause1. Comparing Technologies of Additive Manufacturing for the Development of Vascular Models. Fraunhofer Direct Digital Manufacturing Conference 2016. Full Text – Open Access Publication Date March 2016 How Analyze was Used “The images were reconstructed using a soft-tissue kernel with an isotropic voxel size (edge length…

Myocardial perfusion: characteristics of distal intramyocardial arteriolar trees

Zamir M, Vercnocke AJ, Edwards PK, Anderson JL, Jorgensen SM, Ritman EL. Myocardial perfusion: characteristics of distal intramyocardial arteriolar trees. Ann Biomed Eng. May 2015. Publication Date May 2015 How Analyze was Used “Analysis of the reconstructed micro-CT data was carried out using a dedicated imaging software package (Analyze 11.0).” Keywords Arterioles Blood Flow Velocity…

Impact of plaques in the left coronary artery on wall shear stress and pressure gradient in coronary side branches

Chaichana T, Sun Z, Jewkes J. Impact of plaques in the left coronary artery on wall shear stress and pressure gradient in coronary side branches. Comput Methods Biomech Biomed Engin. January 2014;17(2):108-118. Publication Date January 2014 How Analyze was Used “Volume data were reconstructed at 70–80% RR interval to minimise unwanted artefacts. Image post-processing and…

Investigation of the haemodynamic environment of bifurcation plaques within the left coronary artery in realistic patient models based on CT images

Chaichana T, Sun Z, Jewkes J. Investigation of the haemodynamic environment of bifurcation plaques within the left coronary artery in realistic patient models based on CT images. Australas Phys Eng Sci Med. June 2012;35(2):231-236. Publication Date June 2012 How Analyze was Used “The commercial biomedical imaging software Analyze 7.0 (AnalyzeDirect, Inc., Lenexa, KS, USA) was…

Computational fluid dynamics analysis of the effect of plaques in the left coronary artery

Chaichana T, Sun Z, Jewkes J. Computational fluid dynamics analysis of the effect of plaques in the left coronary artery. Comput Math Methods Med. March 2012;2012:504367. Full Text – Open Access Publication Date March 2012 How Analyze was Used “The original CT data was saved in digital imaging and communication in medicine (DICOM) format and…

A method for quantitative characterization of growth in the 3-D structure of rat pulmonary arteries

Razavi H, Dusch MN, Zarafshar SY, Taylor CA, Feinstein JA. A method for quantitative characterization of growth in the 3-D structure of rat pulmonary arteries. Microvasc Res. March 2012;83(2):146-153. Publication Date March 2012 How Analyze was Used “The image datasets were visualized using volume rendering capabilities of Analyze 10.0 (AnalyzeDirect, Overland Park, KS).” Keywords Age…

Automation process for morphometric analysis of volumetric CT data from pulmonary vasculature in rats

Shingrani R, Krenz G, Molthen R. Automation process for morphometric analysis of volumetric CT data from pulmonary vasculature in rats. Comput Methods Programs Biomed. January 2010;97(1):62-77. Full Text – Open Access Publication Date January 2010 How Analyze was Used “To identify a distal segment at a location along the main trunk, the Tree Analysis module…

Fenestrated stent graft repair of abdominal aortic aneurysm: hemodynamic analysis of the effect of fenestrated stents on the renal arteries

Sun Z, Chaichana T. Fenestrated stent graft repair of abdominal aortic aneurysm: hemodynamic analysis of the effect of fenestrated stents on the renal arteries. Korean J Radiol. January 2010;11(1):95-106. Full Text – Open Access Publication Date January 2010 How Analyze was Used “For generating 3D realistic AAA models, the CT volume data was postprocessed with…

Acquisition of 3-D arterial geometries and integration with computational fluid dynamic

Hammer S, Jeays A, Allan PL, Hose R, Barber D, Easson WJ, Hoskins PR. Acquisition of 3-D arterial geometries and integration with computational fluid dynamics. Ultrasound Med Biol. December 2009;35(12):2069-2083. Publication Date December 2009 How Analyze was Used “The arterial geometry is extracted from the 3-D dataset. A manual method was used, in which points…

Evaluation of porcine myocardial microvascular permeability and fractional vascular volume using 64-slice helical computed tomography (CT)

Daghini E, Primak AN, Chade AR, Zhu X, Ritman EL, McCollough CH, Lerman LO. Evaluation of porcine myocardial microvascular permeability and fractional vascular volume using 64-slice helical computed tomography (CT). Invest Radiol. May 2007;42(5):274-282. Publication Date May 2007 How Analyze was Used “End-diastolic images were analyzed by manually tracing regions of interest (ROI) in the…