Tag Archives: Anatomic Models

3D printing of intracranial aneurysms using fused deposition modeling offers highly accurate replications

Frölich AMJ, Spallek J, Brehmer L, Buhk JH, Krause D, Fiehler J, Kemmling A. 3D printing of intracranial aneurysms using fused deposition modeling offers highly accurate replications. AJNR Am J Neuroradiol. August 2015. Publication Date August 2015 How Analyze was Used “After patient selection, all image data were anonymized. 3D rotational angiographic data were processed…

Virtual reconstruction of the Neanderthal Amud 1 cranium

Amano H, Kikuchi T, Morita Y, Kondo O, Suzuki H, Ponce de Léon MS, Zollikofer CPE, Bastir M, Stringer C, Ogihara N. Virtual reconstruction of the Neanderthal Amud 1 cranium. Am J Phys Anthropol. August 2015. Publication Date August 2015 How Analyze was Used “We used Analyze 9.0 software … to generate three-dimensional (3D) surface…

MRI-determined lumbar muscle morphometry in man and sheep: potential biomechanical implications for ovine model to human spine translation

Valentin S, Licka TF, Elliott J. MRI-determined lumbar muscle morphometry in man and sheep: potential biomechanical implications for ovine model to human spine translation. J Anat. July 2015. Publication Date July 2015 How Analyze was Used “Analyze… software (… Version 11.0) was used for data analysis.” Keywords Humans Lumbar Vertebrae Magnetic Resonance Imaging (MRI) Models,…

Cranial base and posterior cranial vault asymmetry after open and endoscopic repair of isolated lambdoid craniosynostosis

Zubovic E, Woo AS, Skolnick GB, Naidoo SD, Smyth MD, Patel KB. Cranial base and posterior cranial vault asymmetry after open and endoscopic repair of isolated lambdoid craniosynostosis. J Craniofac Surg. June 2015. Publication Date June 2015 How Analyze was Used “Anthropometric measurements were made using the Analyze 11.0 image analysis software… Axial slices from…

Comparison of total lung capacity determined by plethysmography to computed tomographic segmentation analysis

Wylam ME, Matsumoto AJ, Bartholmai BJ. Comparison of total lung capacity determined by plethysmography to computed tomographic segmentation analysis. Abstract. American Thoracic Society International Conference; May 2015, Denver, CO, US. Publication Date May 2015 How Analyze was Used “CT images were analyzed using CALIPER [Analyze], a software program … for 3D modeling and tissue clarification…

Factors affecting dimensional accuracy of 3-D printed anatomical structures derived from CT data

Ogden KM, Aslan C, Ordway N, Diallo D, Tillapaugh-Fay G, Soman P. Factors affecting dimensional accuracy of 3-D printed anatomical structures derived from CT data. J Digit Imaging. May 2015:1-10. Publication Date May 2015 How Analyze was Used “As described in the prior work, the CT data from the L1 vertebra was processed in Analyze…

Unified heat kernel regression for diffusion, kernel smoothing and wavelets on manifolds and its application to mandible growth modeling in CT images

Chung MK, Qiu A, Seo S, Vorperian HK. Unified heat kernel regression for diffusion, kernel smoothing and wavelets on manifolds and its application to mandible growth modeling in CT images. Med Image Anal. May 2015;22(1):63-76. Full Text – Open Access Publication Date May 2015 How Analyze was Used “CT scans were converted to DICOM format…

Validation of radiocarpal joint contact models based on images from a clinical MRI scanner

Johnson JE, McIff TE, Lee P, Toby EB, Fischer KJ. Validation of radiocarpal joint contact models based on images from a clinical MRI scanner. Comput Methods Biomech Biomed Engin. March 2014;17(4):378-387. Full Text – Open Access Publication Date March 2014 How Analyze was Used “Analyze 5.0 (AnalyzeDirect, Overland Park, KS) was used to perform registration…

Repeatability of digital image correlation for measurement of surface strains in composite long bones

Väänänen SP, Amin Yavari S, Weinans H, Zadpoor AA, Jurvelin JS, Isaksson H. Repeatability of digital image correlation for measurement of surface strains in composite long bones. J Biomech. July 2013;46(11):1928-1932. Publication Date July 2013 How Analyze was Used “The CT images of all composite bones were registered to the orientation of bone number 1…

Three-dimensional rapid prototyping models in cranio-maxillofacial surgery: systematic review and new clinical applications

Olszewski R. Three-dimensional rapid prototyping models in cranio-maxillofacial surgery: systematic review and new clinical applications. Proc Belg R Acad Med. March 2013;2:43-77. Full Text – Open Access Publication Date March 2013 How Analyze was Used “A number of software packages are available for data conditioning and image processing for medical RP [rapid prototyping], including Analyze…