Analyze Publications Database

3,721 (and counting) Analyze-related scholarly articles

Most Recent Publications

Optimization of computed tomography pulmonary angiography protocols using 3D printed model with simulation of pulmonary embolism

Sultan Aldosari et al. Optimization of computed tomography pulmonary angiography protocols using 3D printed model with simulation of pulmonary embolism. Quantitative Imaging in Medicine and Surgery. Publication Date October 11 2018 How Analyze was Used “Two-dimensional (2D) images in digital imaging and communications in medicine (DICOM) format were transferred to a workstation with Analyze 12.0…

Findings as a starting point to unravel the underlying mechanisms of in vivo interactions involving Wnt10a in bone, fat and muscle

Manabu Tsukamoto et al. Findings as a starting point to unravel the underlying mechanisms of in vivo interactions involving Wnt10a in bone, fat and muscle. Bone. Publication Date October 11 2018 How Analyze was Used “The bone microstructure parameters in the trabecular bones of distal femoral metaphysis were evaluated using Analyze 12.0 software (AnalyzeDirect, Inc.,…

Age-Related Measurements of the Myelin Water Fraction derived from 3D multi-echo GRASE reflect Myelin Content of the Cerebral White Matter

Tobias D. Faizy et al. Age-Related Measurements of the Myelin Water Fraction derived from 3D multi-echo GRASE reflect Myelin Content of the Cerebral White Matter. Scientific Reports. Publication Date October 9 2018 How Analyze was Used “Regions of Interest (ROI) analysis was performed with the software package Analyze 11.0 (AnalyzeDirect, Overland Park, KS, USA). In…

Early hematoma retraction in intracerebral hemorrhage is uncommon and does not predict outcome

Ana C. Klahr et al. Early hematoma retraction in intracerebral hemorrhage is uncommon and does not predict outcome. PLOS One. Publication Date October 9 2018 How Analyze was Used “Peri-hematoma edema (PHE) volumes were measured using Analyze 11.0. The visibly hypodense region was manually outlined and a threshold of 5 to 23 HU was used…

Regression of cephalic index following endoscopic repair of sagittal synostosis

Nicholas A. Pickersgill et al. Regression of cephalic index following endoscopic repair of sagittal synostosis. Journal of Neurosurgery. Publication Date October 5 2018 How Analyze was Used “CT data were three-dimensionally reconstructed and analyzed using Analyze software (version 12.0).” Keywords Sagittal synostosis, Cephalic index, Plastic surgery, Endoscopic, Regression, Craniofacial Author Affiliation(s) Washington University School of…

Drug holiday in patients with polycystic liver disease treated with somatostatin analogues

RenĂ© M. M. van Aerts et al. Drug holiday in patients with polycystic liver disease treated with somatostatin analogues. Therapeutic Advances in Gastroenterology. Publication Date October 3 2018 How Analyze was Used “Volumetry on MRI was performed with Analyze 11 software (AnalyzeDirect Inc). Liver volume was divided by height to obtain hTLV.” Keywords Drug holiday,…

Minimally Invasive Evacuation of Spontaneous Cerebellar Intracerebral Hemorrhage

Christopher P.Kellner et al. Minimally Invasive Evacuation of Spontaneous Cerebellar Intracerebral Hemorrhage. World Neurosurgery. Publication Date October 3 2018 How Analyze was Used “Hematoma and edema volumes were calculated using semi-automatic threshold-guided volume assessment using the software AnalyzePro (AnalyzeDirect Inc., Overland Park, KS, USA).” Keywords Intracerebral hemorrhage, Minimally invasive, Infratentorial, Craniectomy, Evacuation Author Affiliation(s) Englewood…

A comparison of CT lung voxel density analysis in a blast and non blast injured casualty

Sebastian Bourn et al. A comparison of CT lung voxel density analysis in a blast and non blast injured casualty. Journal of the Royal Army Medical Corps. Publication Date October 3 2018 How Analyze was Used “Tracing the edge of the lung defined multiple 2D regions of interest (ROI), which were then propagated craniocaudally into…

Synchrotron radiation computed tomography assessment of calcified plaques and coronary stenosis with different slice thicknesses and beam energies on 3D printed coronary models

Zhonghua Sun et al. Synchrotron radiation computed tomography assessment of calcified plaques and coronary stenosis with different slice thicknesses and beam energies on 3D printed coronary models. Quantitative Imaging in Medicine and Surgery. Publication Date September 27 2018 How Analyze was Used “Original CCTA images in digital imaging and communications in medicine (DICOM) format were…

Clinical translation of [18F]ICMT-11 for measuring chemotherapy-induced caspase 3/7 activation in breast and lung cancer

S. R. Dubash et al. Clinical translation of [18F]ICMT-11 for measuring chemotherapy-induced caspase 3/7 activation in breast and lung cancer. European Journal of Nuclear Medicine and Molecular Imaging. Publication Date September 27 2018 How Analyze was Used “In both studies, all VOIs were also outlined on fused PET/ CT images to create binary object masks…