Most Recent Publications
Montgomery AJ, Thielemans K, Mehta MA, Turkheimer F, Mustafovic S, Grasby PM. Correction of head movement on PET studies: comparison of methods. J Nucl Med. December 2006;47(12):1936-1944. Full Text – Open Access Publication Date December 2006 How Analyze was Used “Time–activity curves for individual regions were generated using image analysis software (Analyze AVW 4.0).” Keywords…
Cavanaugh D, Travis EL, Price RE, Gladish G, White RA, Wang M, Cody DD. Quantification of bleomycin-induced murine lung damage in vivo with micro-computed tomography. Acad Radiol. December 2006;13(12):1505-1512. Publication Date December 2006 How Analyze was Used “We measured the normal lung volume at baseline and at sacrifice for each calibrated micro-CT image set using…
Booya F, Fletcher JG, Huprich JE, Barlow JM, Johnson CD, Fidler JL, Solem CA, Sandborn WJ, Loftus EV, Jr., Harmsen WS. Active Crohn disease: CT findings and interobserver agreement for enteric phase CT enterography. Radiology. Decembers 2006;241(3):787-795. Full Text – Open Access Publication Date Decembers 2006 How Analyze was Used “We used the line profile…
MacIntyre NJ, Hill NA, Fellows RA, Ellis RE, Wilson DR. Patellofemoral joint kinematics in individuals with and without patellofemoral pain syndrome. J Bone Joint Surg Am. December 2006;88(12):2596-2605. Publication Date December 2006 How Analyze was Used “Each high-resolution scan was segmented to create subject-specific three-dimensional geometricmodels of the proximal part of the tibia, distal part…
Perlyn CA, DeLeon VB, Babbs C, Govier D, Burell L, Darvann T, Kreiborg S, Morriss-Kay G. The craniofacial phenotype of the Crouzon mouse: analysis of a model for syndromic craniosynostosis using three-dimensional MicroCT. Cleft Palate Craniofac J. November 2006;43(6):740-748. Full Text – Open Access Publication Date November 2006 How Analyze was Used “We used ANALYZE…
Cremonini F, Camilleri M, Vazquez Roque M, McKinzie S, Burton D, Baxter K, Zinsmeister AR. Obesity does not increase effects of synthetic ghrelin on human gastric motor functions. Gastroenterology. November 2006;131(5):1431-1439. Publication Date November 2006 How Analyze was Used “A 3-dimensional rendering of the stomach and its volume was obtained using the AVW 3.0.” Keywords…
Matsuoka Y, Nagamine M, Inagaki M, Yoshikawa E, Nakano T, Akechi T, Kobayakawa M, Hara E, Imoto S, Murakami K, Uchitomi Y. Cavum septi pellucidi and intrusive recollections in cancer survivors. Neurosci Res. November 2006;56(3):344-346. Publication Date November 2006 How Analyze was Used “The presence or absence of CSP was then scored on each of…
Buis AWP, Condon B, Brennan D, McHugh B, Hadley D. Magnetic resonance imaging technology in transtibial socket research: a pilot study. J Rehabil Res Dev. November 2006;43(7):883-890. Full Text – Open Access Publication Date November 2006 How Analyze was Used “All DICOM data were exported to the state-of-the-art visualization software Analyze” 5.0 (AnalyzeDirect, Inc; Overland…
Colombel JF, Solem CA, Sandborn WJ, Booya F, Loftus EV, Jr., Harmsen WS, Zinsmeister AR, Bodily KD, Fletcher JG. Quantitative measurement and visual assessment of ileal Crohn’s disease activity by computed tomography enterography: correlation with endoscopic severity and C reactive protein. Gut. November 2006;55(11):1561-1567. Full Text – Open Access Publication Date November 2006 How Analyze…
Gorantla S, Dou H, Boska M, Destache CJ, Nelson J, Poluektova L, Rabinow BE, Gendelman HE, Mosley RL. Quantitative magnetic resonance and SPECT imaging for macrophage tissue migration and nanoformulated drug delivery. J Leukoc Biol. November 2006;80(5):1165-1174. Full Text – Open Access Publication Date November 2006 How Analyze was Used “Reconstructed SPECT images (green) were…