Most Recent Publications
Chuckpaiwong B, Charles HC, Kraus VB, Guilak F, Nunley JA. Age-associated increases in the size of the infrapatellar fat pad in knee osteoarthritis as measured by 3T MRI. J Orthop Res. September 2010;28(9):1149-1154. Full Text – Open Access Publication Date September 2010 How Analyze was Used “The volume of each infrapatellar fat pad was determined…
Isaacson BM, Stinstra JG, MacLeod RS, Pasquina PF, Bloebaum RD. Developing a quantitative measurement system for assessing heterotopic ossification and monitoring the bioelectric metrics from electrically induced osseointegration in the residual limb of service members. Ann Biomed Eng. September 2010;38(9):2968-2978. Full Text – Open Access Publication Date September 2010 How Analyze was Used “The entire…
Litzlbauer HD, Korbel K, Kline TL, Jorgensen SM, Eaker DR, Bohle RM, Ritman EL, Langheinrich AC. Synchrotron-based micro-CT imaging of the human lung acinus. Anat Rec (Hoboken). September 2010;293(9):1607-1614. Full Text – Open Access Publication Date September 2010 How Analyze was Used “The branching angle, the longitudinal length, and the number of segments of each…
Jhoo JH, Lee DY, Choo IH, Seo EH, Oh JS, Lee JS, Lee DS, Kim SG, Youn JC, Kim KW, Woo JI. Discrimination of normal aging, MCI and AD with multimodal imaging measures on the medial temporal lobe. Psychiatry Res. September 2010;183(3):237-243. Publication Date September 2010 How Analyze was Used “The anatomical boundaries of hippocampus…
Miller AM, Bansal R, Hao X, Sanchez-Pena JP, Sobel LJ, Liu J, Xu D, Zhu H, Chakravarty MM, Durkin K, Ivanov I, Plessen KJ, Kellendonk CB, Peterson BS. Enlargement of thalamic nuclei in Tourette syndrome. Arch Gen Psychiatry. September 2010;67(9):955-964. Full Text – Open Access Publication Date September 2010 How Analyze was Used “Morphometric analyses…
Lee SL, Chung A, Lerotic M, Hawkins MA, Tait D, Yang GZ. Dynamic shape instantiation for intra-operative guidance. Med Image Comput Comput Assist Interv. September 2010;13(Pt 1):69-76. Publication Date September 2010 How Analyze was Used “Segmentation and 3D model building were performed in Analyze (AnalyzeDirect, Inc, Overland Park, KS, USA).” Keywords Algorithms Computer Simulation Female…
Langheinrich AC, Yeniguen M, Ostendorf A, Marhoffer S, Dierkes C, von Gerlach S, Nedelmann M, Kampschulte M, Bachmann G, Stolz E, Gerriets T. In vitro evaluation of the sinus sagittalis superior thrombosis model in the rat using 3D micro- and nanocomputed tomography. Neuroradiology. September 2010;52(9):815-821. Publication Date September 2010 How Analyze was Used “The resulting…
Seshadri M, Hoy A. Manganese-enhanced MRI of salivary glands and head and neck tumors in living subjects. Magn Reson Med. September 2010;64(3):902-906. Publication Date September 2010 How Analyze was Used “Following image acquisition, raw image sets were transferred to a processing workstation and converted into Analyze™ format (AnalyzeDirect, version 8.0; Overland Park, KS). Regions of…
Seo S, Chung MK, Vorperian HK. Heat kernel smoothing using Laplace-Beltrami eigenfunctions. Med Image Comput Comput Assist Interv. September 2010;13(Pt 3):505-512. Full Text – Open Access Publication Date September 2010 How Analyze was Used “CT scans were converted to DICOM format and subsequently Analyze 8.1 software package (AnalyzeDirect, Inc., Overland Park, KS) was used in…
Okonkwo OC, Cohen RA, Gunstad J, Tremont G, Alosco ML, Poppas A. Longitudinal trajectories of cognitive decline among older adults with cardiovascular disease. Cerebrovasc Dis. September 2010;30(4):362-373. Full Text – Open Access Publication Date September 2010 How Analyze was Used “Utilizing a semiautomated threshold method in Analyze, the total number of voxels representing white matter…