Analyze Publications Database

3,879 (and counting) Analyze-related scholarly articles

Most Recent Publications

Biomechanical evaluation of an injectable and biodegradable copolymer P(PF-co-CL) in a cadaveric vertebral body defect model

Fang Z, Giambini H, Zeng H, Camp JJ, Dadsetan M, Robb RA, An KN, Yaszemski MJ, Lu L. Biomechanical evaluation of an injectable and biodegradable copolymer P(PF-co-CL) in a cadaveric vertebral body defect model. Tissue Eng Part A. March 2014;20(5-6):1096-1102. Publication Date March 2014 How Analyze was Used “DICOM images obtained during the scanning process…

Breast tissue classifcation in digital tomosynthesis images based on global gradient minimization and texture features

Qin X, Lu G, Sechopoulos I, Fei B. Breast tissue classifcation in digital tomosynthesis images based on global gradient minimization and texture features. Paper presented at: SPIE Medical Imaging 2014: Image Processing, 90341V; March 2014; San Diego, CA US. Publication Date March 2014 How Analyze was Used “In this project, the manual segmentation was performed…

Rationale and design of the DIPAK 1 study: a randomized controlled clinical trial assessing the efficacy of lanreotide to halt disease progression in autosomal dominant polycystic kidney disease

Meijer E, Drenth JP, d’Agnolo H, Casteleijn NF, de Fijter JW, Gevers TJ, Kappert P, Peters DJ, Salih M, Soonawala D, Spithoven EM, Torres VE, Visser FW, Wetzels JF, Zietse R, Gansevoort RT. Rationale and design of the DIPAK 1 study: a randomized controlled clinical trial assessing the efficacy of lanreotide to halt disease progression…

Magnetic resonance imaging of bone and muscle traits at the hip: an in vivo precision study

Johnston JD, Liao L, Dolovich AT, Leswick DA, Kontulainen SA. Magnetic resonance imaging of bone and muscle traits at the hip: an in vivo precision study. J Musculoskelet Neuronal Interact. March 2014;14(1):104-110. Full Text – Open Access Publication Date March 2014 How Analyze was Used “Bone and muscle at the femoral neck and shaft were…

Caspase 3 silencing inhibits biomechanical overload-induced intervertebral disk degeneration

Yamada K, Sudo H, Iwasaki K, Sasaki N, Higashi H, Kameda Y, Ito M, Takahata M, Abumi K, Minami A, Iwasaki N. Caspase 3 silencing inhibits biomechanical overload-induced intervertebral disk degeneration. Am J Pathol. March 2014;184(3):753-764. Publication Date March 2014 How Analyze was Used “Quantitative analysis of the sagittal image slices was also processed using…

Effects of maternal hypothyroidism on offspring hippocampus and memory

Willoughby KA, McAndrews MP, Rovet JF. Effects of maternal hypothyroidism on offspring hippocampus and memory. Thyroid. March 2014;24(3):576-584. Publication Date March 2014 How Analyze was Used “All tracings were carried out manually on a slice-by-slice basis in ANALYZE 9.0 (AnalyzeDirect, Inc., Overland Park, KS).” Keywords Child Congenital Hypothyroidism Hippocampus Memory Pregnancy Author Affiliation(s) Neuroscience and…

Initial evaluation of 18F-GE-179, a putative PET Tracer for activated N-methyl D-aspartate receptors

McGinnity CJ, Hammers A, Riano Barros DA, Luthra SK, Jones PA, Trigg W, Micallef C, Symms MR, Brooks DJ, Koepp MJ, Duncan JS. Initial evaluation of 18F-GE-179, a putative PET Tracer for activated N-methyl D-aspartate receptors. J Nucl Med. March 2014;55(3):423-430. Full Text – Open Access Publication Date March 2014 How Analyze was Used “Global…

Dimensional accuracy of 3D printed vertebra

Ogden K, Ordway N, Diallo D, Tillapaugh-Fay G, Asian C. Dimensional accuracy of 3D printed vertebra. Paper presented at: SPIE Medical Imaging 2014: Image-Guided Procedures, Robotic Interventions, and Modeling, 903610; March 2014; San Diego, CA, US. Publication Date March 2014 How Analyze was Used “The CT scan was downloaded to a local computer for processing…

Mapping cardiac fiber orientations from high-resolution DTI to high-frequency 3D ultrasound

Qin X, Wang S, Shen M, Zhang X, Wagner MB, Fei B. Mapping cardiac fiber orientations from high-resolution DTI to high-frequency 3D ultrasound. Paper presented at: SPIE Medical Imaging 2014: Image-Guided Procedures, Robotic Interventions, and Modeling, March 2014; San Diego, CA, US. Publication Date March 2014 How Analyze was Used “Both ultrasound images and T1…

Muscle-fat magnetic resonance imaging: 1.5 Tesla and 3.0 Tesla versus histology

Smith AC, Parrish TB, Abbott R, Hoggarth MA, Mendoza K, Chen YF, Elliott JM. Muscle-fat magnetic resonance imaging: 1.5 Tesla and 3.0 Tesla versus histology. Muscle Nerve. March 2014. Publication Date March 2014 How Analyze was Used “Analysis of the MR imaging was performed post-hoc using Analyze 11.0 software (AnalyzeDirect…) by 2 investigators experienced in…