Analyze Publications Database

Trabecular bone structure of the calcaneus: comparison of MR imaging at 3.0 and 1.5 T with micro-CT as the standard of reference

Phan CM, Matsuura M, Bauer JS, Dunn TC, Newitt D, Lochmueller EM, Eckstein F, Majumdar S, Link TM. Trabecular bone structure of the calcaneus: comparison of MR imaging at 3.0 and 1.5 T with micro-CT as the standard of reference. Radiology. May 2006;239(2):488-496.

Full Text – Open Access

Publication Date
May 2006

How Analyze was Used
“To better compare images obtained at 1.5 T with those at 3.0 T, dedicated software (Analyze …) based on an isocoordinate base volume registration was used for spatial coregistration to allow for a reliable resampling of the matched volumes during the registration.”

Keywords
Aged
Aged, 80 and over
Cadaver
Calcaneus/anatomy & histology/radiography
Female
Humans
Magnetic Resonance Imaging (MRI)
Male
Middle Aged
Reference Values
Spinal Fractures/diagnosis
Tomography, X-Ray Computed

Author Affiliation(s)
Department of Radiology, University of California, San Francisco, 400 Parnassus Ave, A 367, Box 0628, San Francisco, CA 94143-0628, US. (CMP, JSB, TCD, DN, SM, TML)

Institute for Anatomy, University of Munich, Munich, Germany. (MM)

1st Gynaecology Hospital, LMU, Munich, Germany. (EML)

Institute for Anatomy, Paracelsus Medical Private University, Salzburg, Austria. (FE)

ID# 1879

Tags: , , , , , , , , , , ,