Tag Archives: X-Ray Computed Tomography (CT)/methods

Minimally invasive evaluation of coronary microvascular function by electron beam computed tomography

Mohlenkamp S, Lerman LO, Lerman A, Behrenbeck TR, Katušić ZS, Sheedy PF, 2nd, Ritman EL. Minimally invasive evaluation of coronary microvascular function by electron beam computed tomography. Circulation. November 2000;102(19):2411-2416. Full Text – Open Access Publication Date November 2000 How Analyze was Used “Image data were evaluated with the Analyze software package (Biomedical Imaging Resource)…

Influence of image acquisition parameters on CT artifacts and polyp depiction in spiral CT colonography: in vitro evaluation

Whiting BR, McFarland EG, Brink JA. Influence of image acquisition parameters on CT artifacts and polyp depiction in spiral CT colonography: in vitro evaluation. Radiology. October 2000;217(1):165-172. Full Text – Open Access Publication Date October 2000 How Analyze was Used “For quantitative analysis, the source image data sets were transferred to an independent research workstation…

Measurement of in vivo myocardial microcirculatory function with electron beam CT

Lerman LO, Siripornpitak S, Maffei NL, Sheedy PF, 2nd, Ritman EL. Measurement of in vivo myocardial microcirculatory function with electron beam CT. J Comput Assist Tomogr. May 1999;23(3):390-398. Publication Date May 1999 How Analyze was Used “With use of the image analysis software package Analyze … implemented on the workstation, regions of interest were selected…

Noninvasive technique for measuring in vivo three-dimensional carpal bone kinematics

Crisco JJ, McGovern RD, Wolfe SW. Noninvasive technique for measuring in vivo three-dimensional carpal bone kinematics. J Orthop Res. January 1999;17(1):96-100. Publication Date January 1999 How Analyze was Used “The outer cortical surfaccs of the wrist bones were segmented from the CT volume images by thresholding with use of a three-dimensional biomedical imaging software system…

Spiral CT image deblurring for cochlear implantation

Wang G, Vannier MW, Skinner MW, Cavalcanti MGP, Harding GW. Spiral CT image deblurring for cochlear implantation. IEEE Trans Med Imaging. April 1998;17(2):251-262. Publication Date April 1998 How Analyze was Used “When the Analyze system is used for deblurring [Robb 1995], the ‘wraparound’ artifacts can be suppressed by scaling an image smoothly to zero fromthe…

GI tract unraveling with curved cross sections

Wang G, McFarland EG, Brown BP, Vannier MW. GI tract unraveling with curved cross sections. IEEE Trans Med Imaging. April 1998;17(2):318-322. Publication Date April 1998 How Analyze was Used “Images were displayed using the Voxel Gradient volume rendering algorithm of the Analyze.” Keywords Algorithms Anatomy, Cross-Sectional Colon/radiography Colonic Polyps/radiography Colonoscopy Electric Conductivity Humans Image Processing,…

Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction

Robertson DD, Yuan J, Wang G, Vannier MW. Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction. J Comput Assist Tomogr. March 1997;21(2):293-298. Publication Date March 1997 How Analyze was Used “All reconstructed images were visually assessed for the presence of metal artifact. The accuracy of the cortical bone edges was assessed using ANALYZE™ [Robb…

Craniosynostosis: diagnostic imaging with three-dimensional CT presentation

Vannier MW, Pilgram TK, Marsh JL, Kraemer BB, Rayne SC, Gado MH, Moran CJ, McAlister WH, Shackelford GD, Hardesty RA. Craniosynostosis: diagnostic imaging with three-dimensional CT presentation. AJNR Am J Neuroradiol. November 1994;15(10):1861-1869. Full Text – Open Access Publication Date November 1994 How Analyze was Used “Three- dimensional reconstruction images were created using Analyze software…

Longitudinal image deblurring in spiral CT

Schlueter FJ, Wang G, Hsieh PS, Brink JA, Balfe DM, Vannier MW. Longitudinal image deblurring in spiral CT. Radiology. November 1994;193(2):413-418. Publication Date November 1994 How Analyze was Used “The longitudinal reformation of the step phantom was imported into image analysis software (ANALYZE, version 5.0 …) for image evaluation and processing.” Keywords Technology, Radiologic Tomography,…