Tag Archives: Stents

Horner’s Syndrome following internal carotid artery stent placement

Qureshi MH, Lobanova I, Khan MT, Khan AA, Qureshi AI. Horner’s Syndrome following internal carotid artery stent placement. J Vasc Interv Neurol. November 2014;7(4):36-37. Full Text – Open Access Publication Date November 2014 How Analyze was Used “We photographed the pupils in affected and non-affected sides with a metric scale at baseline, 2 and 5…

Stent revascularization restores cortical blood flow and reverses tissue hypoxia in atherosclerotic renal artery stenosis but fails to reverse inflammatory pathways or glomerular filtration rate

Saad A, Herrmann SM, Crane J, Glockner JF, McKusick MA, Misra S, Eirin A, Ebrahimi B, Lerman LO, Textor SC. Stent revascularization restores cortical blood flow and reverses tissue hypoxia in atherosclerotic renal artery stenosis but fails to reverse inflammatory pathways or glomerular filtration rate. Circ Cardiovasc Interv. August 2013;6(4):428-435. Full Text – Open Access…

Changes in glomerular filtration rate after renal revascularization correlate with microvascular hemodynamics and inflammation in Swine renal artery stenosis

Eirin A, Ebrahimi B, Zhang X, Zhu XY, Tang H, Crane JA, Lerman A, Textor SC, Lerman LO. Changes in glomerular filtration rate after renal revascularization correlate with microvascular hemodynamics and inflammation in Swine renal artery stenosis. Circ Cardiovasc Interv. October 2012;5(5):720-728. Full Text – Open Access Publication Date October 2012 How Analyze was Used…

Ultrasmall superparamagnetic particles of iron oxide in patients with acute myocardial infarction: early clinical experience

Alam SR, Shah ASV, Richards J, Lang NN, Barnes G, Joshi N, MacGillivray T, McKillop G, Mirsadraee S, Payne J, Fox KAA, Henriksen P, Newby DE, Semple SIK. Ultrasmall superparamagnetic particles of iron oxide in patients with acute myocardial infarction: early clinical experience. Circ Cardiovasc Imaging. September 2012;5(5):559-565. Full Text – Open Access Publication Date…

Revascularization of swine renal artery stenosis improves renal function but not the changes in vascular structure

Favreau F, Zhu XY, Krier JD, Lin J, Warner L, Textor SC, Lerman LO. Revascularization of swine renal artery stenosis improves renal function but not the changes in vascular structure. Kidney Int. December 2010;78(11):1110-1118. Full Text – Open Access Publication Date December 2010 How Analyze was Used “MDCT images were reconstructed and displayed with the…

Dual-source CT angiography in aortic stent grafting: an in vitro aorta phantom study of image noise and radiation dose

Sun Z, Ng C. Dual-source CT angiography in aortic stent grafting: an in vitro aorta phantom study of image noise and radiation dose. Acad Radiol. July 2010;17(7):884-893. Publication Date July 2010 How Analyze was Used “MSCT volume data were converted from original digital imaging and communication in medicine images with a commercially available software Analyze…

Optimal scanning protocols of 64-slice CT angiography in coronary artery stents: an in vitro phantom study

Almutairi AM, Sun Z, Ng C, Al-Safran ZA, Al-Mulla AA, Al-Jamaan AI. Optimal scanning protocols of 64-slice CT angiography in coronary artery stents: an in vitro phantom study. Eur J Radiol. April 2010;74(1):156-160. Publication Date April 2010 How Analyze was Used “All of the DICOM images were later transferred to a workstation equipped with commercially…

Fenestrated stent graft repair of abdominal aortic aneurysm: hemodynamic analysis of the effect of fenestrated stents on the renal arteries

Sun Z, Chaichana T. Fenestrated stent graft repair of abdominal aortic aneurysm: hemodynamic analysis of the effect of fenestrated stents on the renal arteries. Korean J Radiol. January 2010;11(1):95-106. Full Text – Open Access Publication Date January 2010 How Analyze was Used “For generating 3D realistic AAA models, the CT volume data was postprocessed with…

Computed tomography virtual intravascular endoscopy in the evaluation of fenestrated stent graft repair of abdominal aortic aneurysms

Sun Z, Mwipatayi BP, Allen YB, Hartley DE, Lawrence-Brown MMD. Computed tomography virtual intravascular endoscopy in the evaluation of fenestrated stent graft repair of abdominal aortic aneurysms. ANZ J Surg. November 2009;79(11):836-840. Full Text – Open Access Publication Date November 2009 How Analyze was Used “Original digital imaging and communication in medicine data of pre…

3D stereoscopic visualization of fenestrated stent grafts

Sun Z, Squelch A, Bartlett A, Cunningham K, Lawrence-Brown M. 3D stereoscopic visualization of fenestrated stent grafts. Cardiovasc Intervent Radiol. September 2009;32(5):1053-1058. Publication Date September 2009 How Analyze was Used “All of the DICOM data were also transferred to another workstation equipped with Analyze V 7.0 (AnalyzeDirect Inc., Lenexa, KS) for generation of the 3D…