Tag Archives: Reproducibility of Results

Automated quantification of keratocyte density by using confocal microscopy in vivo

Patel SV, McLaren JW, Camp JJ, Nelson LR, Bourne WM. Automated quantification of keratocyte density by using confocal microscopy in vivo. Invest Ophthalmol Vis Sci. February 1999;40(2):320-326. Full Text – Open Access Publication Date February 1999 How Analyze was Used “All image processing was performed by a custom program [Hanson et al. 1997, Robb and…

Determination of tumour regression rates during radiotherapy for cervical carcinoma by serial MRI: comparison of two measurement techniques and examination of intraobserver and interobserver variability

Gong QY, Tan LT, Romaniuk CS, Jones B, Brunt JN, Roberts N. Determination of tumour regression rates during radiotherapy for cervical carcinoma by serial MRI: comparison of two measurement techniques and examination of intraobserver and interobserver variability. Br J Radiol. January 1999;72(853):62-72. Publication Date January 1999 How Analyze was Used “Point counting was performed on…

Noninvasive technique for measuring in vivo three-dimensional carpal bone kinematics

Crisco JJ, McGovern RD, Wolfe SW. Noninvasive technique for measuring in vivo three-dimensional carpal bone kinematics. J Orthop Res. January 1999;17(1):96-100. Publication Date January 1999 How Analyze was Used “The outer cortical surfaccs of the wrist bones were segmented from the CT volume images by thresholding with use of a three-dimensional biomedical imaging software system…

Comparison of reliability of manual and computer-intensive methods for radiodensity measures of alveolar bone loss

Hildebolt CF, Brunsden B, Yokoyama-Crothers N, Pilgram TK, Townsend KE, Vannier MW, Shrout MK. Comparison of reliability of manual and computer-intensive methods for radiodensity measures of alveolar bone loss. Dentomaxillofac Radiol. July 1998;27(4):245-250. Full Text – Open Access Publication Date July 1998 How Analyze was Used “For the computer-intensive method, images were put into registration…

Spiral CT image deblurring for cochlear implantation

Wang G, Vannier MW, Skinner MW, Cavalcanti MGP, Harding GW. Spiral CT image deblurring for cochlear implantation. IEEE Trans Med Imaging. April 1998;17(2):251-262. Publication Date April 1998 How Analyze was Used “When the Analyze system is used for deblurring [Robb 1995], the ‘wraparound’ artifacts can be suppressed by scaling an image smoothly to zero fromthe…

Subtraction ictal SPECT co-registered to MRI improves clinical usefulness of SPECT in localizing the surgical seizure focus

O’Brien TJ, So EL, Mullan BP, Hauser MF, Brinkmann BH, Bohnen NI, Hanson D, Cascino GD, Jack CR, Jr., Sharbrough FW. Subtraction ictal SPECT co-registered to MRI improves clinical usefulness of SPECT in localizing the surgical seizure focus. Neurology. February 1998;50(2):445-454. Publication Date February 1998 How Analyze was Used “SISCOM images were constructed on an…

MRI lesion volume measurement in multiple sclerosis and its correlation with disability: a comparison of fast fluid attenuated inversion recovery (fFLAIR) and spin echo sequences

Gawne-Cain ML, O’Riordan JI, Coles A, Newell B, Thompson AJ, Miller DH. MRI lesion volume measurement in multiple sclerosis and its correlation with disability: a comparison of fast fluid attenuated inversion recovery (fFLAIR) and spin echo sequences. J Neurol Neurosurg Psychiatry. February 1998;64(2):197-203. Full Text – Open Access Publication Date February 1998 How Analyze was…

Subtraction ictal SPET co-registered to MRI in partial epilepsy: description and technical validation of the method with phantom and patient studies

O’Brien TJ, O’Connor MK, Mullan BP, Brinkmann BH, Hanson D, Jack CR, So EL. Subtraction ictal SPET co-registered to MRI in partial epilepsy: description and technical validation of the method with phantom and patient studies. Nucl Med Commun. January 1998;19(1):31-45. Publication Date January 1998 How Analyze was Used “The SISCOM images were constructed on an…

Baboon basal ganglia stereotaxy using internal MRI landmarks: validation and application to PET imaging

Black KJ, Gado MH, Videen TO, Perlmutter JS. Baboon basal ganglia stereotaxy using internal MRI landmarks: validation and application to PET imaging. J Comput Assist Tomogr. November 1997;21(6):881-886. Publication Date November 1997 How Analyze was Used “Under visual guidance and using ANALYZE v7.0 …, a single operator measured the angles by which each MR image…

Quantification of phosphorus metabolites in human calf muscle and soft-tissue tumours from localized MR spectra acquired using surface coils

Doyle VL, Payne GS, Collins DJ, Verrill MW, Leach MO. Quantification of phosphorus metabolites in human calf muscle and soft-tissue tumours from localized MR spectra acquired using surface coils. Phys Med Biol. April 1997;42(4):691-706. Publication Date April 1997 How Analyze was Used “The anatomical images were displayed using ANALYZE Version 7.5.” Keywords Adenosine Triphosphate/metabolism Gadolinium/diagnostic…