Tag Archives: Prosthesis Failure

Can microcomputed tomography measure retrieved polyethylene wear? Comparing fixed-bearing and rotating-platform knees

Engh CA, Jr., Zimmerman RL, Hopper RH, Jr., Engh GA. Can microcomputed tomography measure retrieved polyethylene wear? Comparing fixed-bearing and rotating-platform knees. Clin Orthop Relat Res. January 2013;471(1):86-93. Full Text – Open Access Publication Date January 2013 How Analyze was Used “The DICOM-formatted image data were then imported into three-dimensional image analysis software…(Analyze 9.0; AnalyzeDirect,…

Mineralisation and mechanical strength of the glenoid cavity subchondral bone plate

Kraljević M, Zumstein V, Wirz D, Hügli R, Müller-Gerbl M. Mineralisation and mechanical strength of the glenoid cavity subchondral bone plate. Int Orthop. December 2011;35(12):1813-1819. Full Text – Open Access Publication Date December 2011 How Analyze was Used “Axial section thickness was set to 0.6 mm, and data were evaluated using the image analysing system…

The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene

Mall NA, Nunley RM, Zhu JJ, Maloney WJ, Barrack RL, Clohisy JC. The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene. Clin Orthop Relat Res. February 2011;469(2):372-381. Full Text – Open Access Publication Date February 2011 How Analyze was Used “Segmentation and volume calculations were performed using Analyze software (Version…

A comparison of a second- and a third-generation modular cup design: is new improved?

Powers CC, Ho H, Beykirch SE, Huynh C, Hopper RH, Jr., Engh CA, Jr., Engh CA. A comparison of a second- and a third-generation modular cup design: is new improved? J Arthroplasty. June 2010;25(4):514-521. Publication Date June 2010 How Analyze was Used “To analyze the CT image, the DICOM-formatted image data were transferred to a…

Incidence, anatomical location, and clinical significance of compressions and fractures in infrapopliteal balloon-expandable metal stents

Karnabatidis D, Katsanos K, Spiliopoulos S, Diamantopoulos A, Kagadis GC, Siablis D. Incidence, anatomical location, and clinical significance of compressions and fractures in infrapopliteal balloon-expandable metal stents. J Endovasc Ther. February 2009;16(1):15-22. Publication Date February 2009 How Analyze was Used “Digital images were then transferred to the Department of Medical Physics for processing using the…

Particle-induced osteolysis in three-dimensional micro-computed tomography

Wedemeyer C, Xu J, Neuerburg C, Landgraeber S, Malyar NM, von Knoch F, Gosheger G, von Knoch M, Löer F, Saxler G. Particle-induced osteolysis in three-dimensional micro-computed tomography. Calcif Tissue Int. November 2007;81(5):394-402. Publication Date November 2007 How Analyze was Used “For qualitative analysis, 3D images of the mice heads were then reconstructed from the…

Migration of uncemented, long-stem femoral components in revision hip arthroplasty. A 2-8 year clinical follow-up of 45 cases and radiostereometric analysis of 13 cases

Önsten I, Sanzén L, Carlsson A, Besjakov J. Migration of uncemented, long-stem femoral components in revision hip arthroplasty. A 2-8 year clinical follow-up of 45 cases and radiostereometric analysis of 13 cases. Acta Orthop Scand. June 1995;66(3):220-224. Publication Date June 1995 How Analyze was Used “In the RSA-series, prosthetic fill was evaluated from standard postoperative…