Tag Archives: Prosthesis Design

Engineering patient-specific drill templates and bioabsorbable posterior cervical plates: a feasibility study

Ryken TC, Kim J, Owen BD, Christensen GE, Reinhardt JM. Engineering patient-specific drill templates and bioabsorbable posterior cervical plates: a feasibility study. J Neurosurg Spine. February 2009;10(2):129-132. Publication Date February 2009 How Analyze was Used “Software used for drill template and cervical plate construction included the software associated with the Stealth Image Guided Workstation 3D…

Incidence, anatomical location, and clinical significance of compressions and fractures in infrapopliteal balloon-expandable metal stents

Karnabatidis D, Katsanos K, Spiliopoulos S, Diamantopoulos A, Kagadis GC, Siablis D. Incidence, anatomical location, and clinical significance of compressions and fractures in infrapopliteal balloon-expandable metal stents. J Endovasc Ther. February 2009;16(1):15-22. Publication Date February 2009 How Analyze was Used “Digital images were then transferred to the Department of Medical Physics for processing using the…

CT virtual intravascular endoscopy in the visualization of fenestrated stent-grafts

Sun Z, Allen YB, Nadkarni S, Knight R, Hartley DE, Lawrence-Brown MMD. CT virtual intravascular endoscopy in the visualization of fenestrated stent-grafts. J Endovasc Ther. February 2008;15(1):42-51. Publication Date February 2008 How Analyze was Used “All CT data were transferred to a workstation equipped with Analyze software (version 7.0; AnalyzeDirect, Inc., Lenexa, KS, USA) for…

Suprarenal fixation of endovascular aortic stent grafts: assessment of medium-term to long-term renal function by analysis of juxtarenal stent morphology

O’Donnell ME, Sun Z, Winder RJ, Ellis PK, Lau LL, Blair PH. Suprarenal fixation of endovascular aortic stent grafts: assessment of medium-term to long-term renal function by analysis of juxtarenal stent morphology. J Vasc Surg. April 2007;45(4):694-700. Full Text – Open Access Publication Date April 2007 How Analyze was Used “Virtual endoscopic images of the…

Magnetic resonance imaging technology in transtibial socket research: a pilot study

Buis AWP, Condon B, Brennan D, McHugh B, Hadley D. Magnetic resonance imaging technology in transtibial socket research: a pilot study. J Rehabil Res Dev. November 2006;43(7):883-890. Full Text – Open Access Publication Date November 2006 How Analyze was Used “All DICOM data were exported to the state-of-the-art visualization software Analyze” 5.0 (AnalyzeDirect, Inc; Overland…

Custom implant design for patients with cranial defects

Lee MY, Chang CC, Lin CC, Lo LJ, Chen YR. Custom implant design for patients with cranial defects. IEEE Eng Med Biol Mag. March 2002;21(2):38-44. Publication Date March 2002 How Analyze was Used “The serial CT image data were reformatted in an IBM-compatible personal computer running AnalyzePC 3.0 software.” Keywords Bone Plates Child Computer Simulation…

Chronic electrical stimulation of the auditory nerve using high surface area (HiQ) platinum electrodes

Tykocinski M, Duan Y, Tabor B, Cowan RS. Chronic electrical stimulation of the auditory nerve using high surface area (HiQ) platinum electrodes. Hear Res. September 2001;159(1-2):53-68. Publication Date September 2001 How Analyze was Used “Following the digitization of the cochleas as described above, ‘Analy[z]e’ software … was used to mark the following histological structures of…

Effect of femoral head design, cup orientation, and wear on hip range of motion

Mattessich S, Nakamura Y, Elias J, Mont M, Wenz J, Chao E. Effect of femoral head design, cup orientation, and wear on hip range of motion. Paper presented at: 46th Annual Meeting, Orthopaedic Research Society, March 2000; Orlando, FL, US. Publication Date March 2000 How Analyze was Used “The reconstruction process used contouring algorithms from…

Autogenous onlay grafting for enhancement of extracortical tissue formation over porous-coated segmental replacement prostheses

Virolainen P, Inoue N, Nagao M, Ohnishi I, Frassica F, Chao EY. Autogenous onlay grafting for enhancement of extracortical tissue formation over porous-coated segmental replacement prostheses. J Bone Joint Surg Am. April 1999;81(4):493-499. Publication Date April 1999 How Analyze was Used “The computed tomography scans were analyzed with a three-dimensional reconstruction software package (Analyze 7.5…

Three-dimensional lower-extremity residua measurement systems error analysis

Vannier MW, Commean PK, Smith KE. Three-dimensional lower-extremity residua measurement systems error analysis. Abstract. J Prosthet Orthot. March 1997;9(2):67-76. Full Text – Open Access Publication Date March 1997 How Analyze was Used “The three-dimensional voxel images were read into ANALYZE™ … software.” Keywords Adult Amputees Electromagnetic Phenomena Evaluation Studies Humans Imaging, Three-Dimensional Lower Extremity Prosthesis…