Tag Archives: Observer Variation

Perfusion SPECT, SISCOM and PET 18F-FDG in the assessment of drug-refractory epilepsy patients candidates for epilepsy surgery

Suárez-Piñera M, Mestre-Fusco A, Ley M, González S, Medrano S, Principe A, Mojal S, Conesa G, Rocamora R. Perfusion SPECT, SISCOM and PET 18F-FDG in the assessment of drug-refractory epilepsy patients candidates for epilepsy surgery. Rev Esp Med Nucl Imagen Mol. June 2015. Publication Date June 2015 How Analyze was Used “99mTc-HMPAO SPECT ictal-interictal and…

Validation of intracerebral hemorrhage-specific intensity of care quality metrics

Qureshi AI, Majidi S, Chaudhry SA, Qureshi MH, Suri MF. Validation of intracerebral hemorrhage-specific intensity of care quality metrics. J Stroke Cerebrovasc Dis. July 2013;22(5):661-667. Publication Date July 2013 How Analyze was Used “The core laboratory neuroimaging personnel, who were blinded to the performance on quality indicators and clinical findings, reviewed all CT scans and…

Volumetric analysis of subarachnoid hemorrhage: assessment of the reliability of two computerized methods and their comparison with other radiographic scales

Jiménez-Roldán L, Alén JF, Gómez PA, Lobato RD, Ramos A, Munarriz PM, Lagares A. Volumetric analysis of subarachnoid hemorrhage: assessment of the reliability of two computerized methods and their comparison with other radiographic scales. J Neurosurg. January 2013;118(1):84-93. Full Text – Open Access Publication Date January 2013 How Analyze was Used “The images were stored…

Median nerve deformation in differential finger motions: ultrasonographic comparison of carpal tunnel syndrome patients and healthy controls

van Doesburg MH, Henderson J, Yoshii Y, Mink van der Molen AB, Cha SS, An KN, Amadio PC. Median nerve deformation in differential finger motions: ultrasonographic comparison of carpal tunnel syndrome patients and healthy controls. J Orthop Res. April 2012;30(4):643-648. Full Text – Open Access Publication Date April 2012 How Analyze was Used “Five cycles…

Apical morphology of the palatal roots of maxillary molars by using micro-computed tomography

Meder-Cowherd L, Williamson AE, Johnson WT, Vasilescu D, Walton R, Qian F. Apical morphology of the palatal roots of maxillary molars by using micro-computed tomography. J Endod. August 2011;37(8):1162-1165. Publication Date August 2011 How Analyze was Used “3D image processing of the cropped slices was performed by using Analyze (AnalyzeDirect, Inc, Overland Park, KS).” Keywords…

Frequency of adequate contrast opacification of the major intracranial venous structures with CT angiography in the setting of intracerebral hemorrhage: comparison of 16- and 64-section CT angiography techniques

Delgado Almandoz JE, Su HS, Schaefer PW, Goldstein JN, Pomerantz SR, Lev MH, Gonzalez RG, Romero JM. Frequency of adequate contrast opacification of the major intracranial venous structures with CT angiography in the setting of intracerebral hemorrhage: comparison of 16- and 64-section CT angiography techniques. AJNR Am J Neuroradiol. May 2011;32(5):839-845. Full Text – Open…

Observer-independent characterization of sulcal landmarks and depth asymmetry in the central sulcus of the chimpanzee brain

Hopkins WD, Coulon O, Mangin JF. Observer-independent characterization of sulcal landmarks and depth asymmetry in the central sulcus of the chimpanzee brain. Neuroscience. December 2010;171(2):544-551. Full Text – Open Access Publication Date December 2010 How Analyze was Used “The archived MRI data were transferred to a PC running Analyze 8.1 … software for post-image processing.”…

New multispectral MRI data fusion technique for white matter lesion segmentation: method and comparison with thresholding in FLAIR images

Valdés Hernández MC, Ferguson KJ, Chappell FM, Wardlaw JM. New multispectral MRI data fusion technique for white matter lesion segmentation: method and comparison with thresholding in FLAIR images. Eur Radiol. July 2010;20(7):1684-1691. Full Text – Open Access Publication Date July 2010 How Analyze was Used “To determine the best and most subject-specific thresholds, we sampled…

Diffuse damage in pediatric traumatic brain injury: a comparison of automated versus operator-controlled quantification methods

Bigler ED, Abildskov TJ, Wilde EA, McCauley SR, Li X, Merkley TL, Fearing MA, Newsome MR, Scheibel RS, Hunter JV, Chu Z, Levin HS. Diffuse damage in pediatric traumatic brain injury: a comparison of automated versus operator-controlled quantification methods. Neuroimage. April 2010;50(3):1017-1026. Publication Date April 2010 How Analyze was Used “Using operator-controlled ANALYZE® 7.0 …,…

Development and evaluation of a semiautomatic segmentation method for the estimation of LV parameters on cine MR images

Mazonakis M, Grinias E, Pagonidis K, Tziritas G, Damilakis J. Development and evaluation of a semiautomatic segmentation method for the estimation of LV parameters on cine MR images. Phys Med Biol. February 2010;55(4):1127-1140. Publication Date February 2010 How Analyze was Used “All short-axis images were transferred to a workstation equipped with Analyze 3.1 image analysis…