Tag Archives: Liver

Deciphering the decline of metabolic elasticity in aging and obesity

Qiuzhong Zhou et al. Deciphering the decline of metabolic elasticity in aging and obesity Cell Metabolism. Publication Date August 24, 2023 How Analyze was Used “The bones were then stained for 48 hours in 1% osmium tetroxide, 2.5% potassium dichromate solution at RT, washed in tap water for at least 2 hours, and imaged by…

3D-Printed multi-material liver model with simultaneous mechanical and radiological tissue-mimicking features for improved realism

Laszlo Jaksa et al. 3D-Printed multi-material liver model with simultaneous mechanical and radiological tissue-mimicking features for improved realism International Journal of Bioprinting. Publication Date March 28, 2023 How Analyze was Used “For all sample scans, a smooth J30s reconstruction kernel was applied. Analyze 12.0 toolkit (AnalyzeDirect, Overland Park, KS) was used to estimate the average Hounsfield…

Fully-automated, high-throughput micro-computed tomography analysis of body composition enables therapeutic efficacy monitoring in preclinical models

Wyatt SK, Barck KH, Kates L, Zavala-Solorio J, Ross J, Kolumam G, Sonoda J, Carano RA. Fully-automated, high-throughput micro-computed tomography analysis of body composition enables therapeutic efficacy monitoring in preclinical models. Int J Obes (Lond). June 2015. Publication Date June 2015 How Analyze was Used “An automatic image analysis algorithm was developed using the C++…

Volume regression of native polycystic kidneys after renal transplantation

Jung Y, Irazabal MV, Chebib FT, Harris PC, Dean PG, Prieto M, Cosio FG, El-Zoghby ZM, Torres VE. Volume regression of native polycystic kidneys after renal transplantation. Nephrol Dial Transplant. June 2015. Publication Date June 2015 How Analyze was Used “Total kidney volume (TKV) was evaluated by a single investigator (YJ) without knowledge of the…

Metabolically normal obese people are protected from adverse effects following weight gain

Fabbrini E, Yoshino J, Yoshino M, Magkos F, Tiemann Luecking C, Samovski D, Fraterrigo G, Okunade AL, Patterson BW, Klein S. Metabolically normal obese people are protected from adverse effects following weight gain. J Clin Invest. January 2015. Full Text – Open Access Publication Date January 2015 How Analyze was Used “Body FM [fat mass]…

A mechanics-based nonrigid registration method for liver surgery using sparse intraoperative data

Rucker D, Wu Y, Clements L, Ondrake J, Pheiffer T, Simpson A, Jarnagin W, Miga M. A mechanics-based nonrigid registration method for liver surgery using sparse intraoperative data. IEEE Trans Med Imaging. September 2013. Publication Date September 2013 How Analyze was Used “For the phantom cases studied in Section IV, we manually segmented the liver…

Tracking alignment of sparse ultrasound with preoperative images of the liver and an interventional plan using models of respiratory motion and deformation

Blackall JM, Penney GP, King AP, Adam AN, Hawkes DJ. Tracking alignment of sparse ultrasound with preoperative images of the liver and an interventional plan using models of respiratory motion and deformation. Paper presented at: Medical Imaging 2004: Visualization, Image-Guided Procedures, and Display, February 2004; San Diego, CA, US. Publication Date February 2004 How Analyze…

Incorporation of a laser range scanner into an image-guided surgical system

Cash DM, Sinha TK, Chapman WC, Terawaki H, Miga MI, Galloway Jr RL. Incorporation of a laser range scanner into an image-guided surgical system. Paper presented at: Medical Imaging 2003: Visualization, Image-Guided Procedures, and Display, February 2003. Publication Date February 2003 How Analyze was Used “Some segmentation and calculation were performed using Analyze AVW Version…

Intraoperative registration of the liver for image-guided surgery using laser range scanning and deformable models

Miga MI, Cash DM, Cao Z, Galloway Jr RL, Dawant BM, Chapman WC. Intraoperative registration of the liver for image-guided surgery using laser range scanning and deformable models. Paper presented at: Medical Imaging 2003: Visualization, Image-Guided Procedures, and Display, February 2003; San Diego, CA, US. Publication Date February 2003 How Analyze was Used “Some segmentation…

Fast accurate surface acquisition using a laser range scanner for image-guided liver surgery

Cash DM, Sinha TK, Chapman WC, Galloway Jr RL, Miga MI. Fast accurate surface acquisition using a laser range scanner for image-guided liver surgery. Paper presented at: Medical Imaging 2002: Visualization, Image-Guided Procedures, and Display, February 2002; San Diego, CA, US. Publication Date February 2002 How Analyze was Used “In the CT volume, each sphere…