Tag Archives: Finite Element Analysis

Medical imaging genesis for finite element-based mandibular surgical planning in the pediatric subject

Zhao L, Patel PK, Widera GEO, Han H, Harris GF. Medical imaging genesis for finite element-based mandibular surgical planning in the pediatric subject. Paper presented at: Engineering in Medicine and Biology Society, 2001. Proceedings of the 23rd Annual International Conference of the IEEE, October 2001. Publication Date October 2001 How Analyze was Used “The geometric…

A constrained modulus reconstruction technique for breast cancer assessment

Samani A, Bishop J, Plewes DB. A constrained modulus reconstruction technique for breast cancer assessment. IEEE Trans Med Imaging. September 2001;20(9):877-885. Publication Date September 2001 How Analyze was Used “AnalyzeAVW V 2.5 …: an image analysis package was used for image segmentation on the basis of image signal level.” Keywords Breast Neoplasms/diagnosis Female Finite Element…

Biomechanical 3-D finite element modeling of the human breast using MRI data

Samani A, Bishop J, Yaffe MJ, Plewes DB. Biomechanical 3-D finite element modeling of the human breast using MRI data. IEEE Trans Med Imaging. April 2001;20(4):271-279. Publication Date April 2001 How Analyze was Used “For segmentation, 3-D MRI data of the breast is converted into AnalyzeAVW 2.5 … database where a standard thresholding-based tool was…

Finite element modeling of tissue retraction and resection for preoperative neuroimage compensation concurrent with surgery

Paulsen KD, Miga MI, Roberts DW, Kennedy FE, Platenik LA, Lunn KE, Hartov A. Finite element modeling of tissue retraction and resection for preoperative neuroimage compensation concurrent with surgery. Paper presented at: Medical Imaging 2001: Visualization, Display, and Image-Guided Procedures,  February 2001; San Diego, CA, US. Publication Date February 2001 How Analyze was Used “The…

Intraoperatively updated neuroimaging using brain modeling and sparse data

Roberts DW, Miga MI, Hartov A, Eisner S, Lemery JM, Kennedy FE, Paulsen KD. Intraoperatively updated neuroimaging using brain modeling and sparse data. Abstract. Neurosurgery. November 1999;45(5):1199. Publication Date November 1999 How Analyze was Used “This mesh is generated through a series of steps beginning with the preoperative MRI series. Scan data are imported into…

Effect of cell migration on the maintenance of tension on a collagen matrix

Roy P, Petroll WM, Chuong CJ, Cavanagh HD, Jester JV. Effect of cell migration on the maintenance of tension on a collagen matrix. Ann Biomed Eng. November 1999;27(6):721-730. Publication Date November 1999 How Analyze was Used “These individual images were assembled into a temporal-sequence image file using ANALYZE software version 5.0 … running on a…

Intraoperatively updated neuroimaging using brain modeling and sparse data

Roberts DW, Miga MI, Hartov A, Eisner S, Lemery JM, Kennedy FE, Paulsen KD. Intraoperatively updated neuroimaging using brain modeling and sparse data. Neurosurgery. November 1999;45(5):1199-1206; discussion 1206-1197. Publication Date November 1999 How Analyze was Used “Scan data are imported into ANALYZE … and the cranium is removed through manual tissue segmentation.” Keywords Adult Brain…

Model-updated image-guided neurosurgery using the finite element method: incorporation of the falx cerebri

Miga MI, Paulsen KD, Kennedy FE, Hartov A, Roberts DW. Model-updated image-guided neurosurgery using the finite element method: incorporation of the falx cerebri. In: Taylor C, Colchester ACF, eds. Medical image computing and computer-assisted intervention–MICCAI ’99 : second international conference, Cambridge, UK, September 19-22, 1999 proceedings. New York: Springer; 1999:900-909. Publication Date September 1999 How…

A 3D brain deformation model experiencing comparable surgical loads

Miga M, Paulsen KD, Kennedy FE, Hoopes PJ, Hartov A, Roberts DW. A 3D brain deformation model experiencing comparable surgical loads. Paper presented at: Engineering in Medicine and Biology Society, 1997. Proceedings of the 19th Annual International Conference of the IEEE; November 1997, Chicago, IL, US. Publication Date November 1997 How Analyze was Used “We…

Precision and accuracy of 3D lower extremity residua measurement systems

Commean PK, Smith KE, Vannier MW, Hildebolt CF, Pilgram TK. Precision and accuracy of 3D lower extremity residua measurement systems. Paper presented at: Medical Imaging 1996: Image Processing; February 1996, Newport Beach, CA, US. Publication Date February 1996 How Analyze was Used “The 3D voxel images were read into ANALYZE … software. The 1.5 mm…