Tag Archives: Evaluation Studies as Topic

3D printing of intracranial aneurysms using fused deposition modeling offers highly accurate replications

Frölich AMJ, Spallek J, Brehmer L, Buhk JH, Krause D, Fiehler J, Kemmling A. 3D printing of intracranial aneurysms using fused deposition modeling offers highly accurate replications. AJNR Am J Neuroradiol. August 2015. Publication Date August 2015 How Analyze was Used “After patient selection, all image data were anonymized. 3D rotational angiographic data were processed…

Using pneumo-computerized tomography as a quantitative assessment of result in submucous fibrosis patients treated with surgical release and free flap reconstruction

Chang CC, Ng SH, Lam WL, Tsai CY, Chang YM, Wei FC. Using pneumo-computerized tomography as a quantitative assessment of result in submucous fibrosis patients treated with surgical release and free flap reconstruction. J Craniofac Surg. November 2014;25(6):1943-1946. Publication Date November 2014 How Analyze was Used “The preoperative and postoperative buccal vestibular volumes were determined…

Cartilage deformation under load in a human cadaveric hip measured with 7.0 T qMRI

Greaves L, Gilbart M, Yung A, Kozlowski P, Wilson D. Cartilage deformation under load in a human cadaveric hip measured with 7.0 T qMRI. Paper presented at: ISMRM 16th Scientific Meeting and Exhibition; May 2008, Toronto. Publication Date May 2008 How Analyze was Used “For each time interval during deformation and recovery phases, the osseous…

Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis

Chow TW, Takeshita S, Honjo K, Pataky CE, St Jacques PL, Kusano ML, Caldwell CB, Ramirez J, Black S, Verhoeff NPLG. Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis. BMC Nucl Med. January 2007;7:2. Full Text – Open Access Publication Date January 2007 How Analyze was Used “Identification…

Noninvasive evaluation of a novel swine model of renal artery stenosis

Lerman LO, Schwartz RS, Grande JP, Sheedy PF, Romero JC. Noninvasive evaluation of a novel swine model of renal artery stenosis. J Am Soc Nephrol. July 1999;10(7):1455-1465. Full Text – Open Access Publication Date July 1999 How Analyze was Used “All images were reconstructed using a standard tomographic algorithm and displayed on a Sun® ……

Evaluating virtual endoscopy for clinical use

Blezek DJ, Robb RA. Evaluating virtual endoscopy for clinical use. J Digit Imaging. August 1997;10(3 Suppl 1):51-55. Full Text – Open Access Publication Date August 1997 How Analyze was Used “Tumor response studies could be signifi- cantly augmented by virtual endoscopy, coupled with powerful analysis tools such as AnalyzeAVW.” Keywords Algorithms Anatomy, Cross-Sectional Bronchi/anatomy &…

Comparative estimation of orbital three dimensional CT measurements utilizing Analyze™

Bite U, Yugueros P, TerKonda S, D’Souza D. Comparative estimation of orbital three dimensional CT measurements utilizing Analyze™. In: Troccaz J, Grimson E, Mösges R, eds. CVRMed-MRCAS’97: First Joint Conference Computer Vision, Virtual Reality and Robotics in Medicine and Medical Robotics and Computer-Assisted Surgery, Grenoble, France, March 19–22, 1997: proceedings. Berlin: Springer; 1997:93-96. Publication Date…

Spiral CT refines imaging of temporal bone disorders

Vannier MW, Wang GE. Spiral CT refines imaging of temporal bone disorders. Diagn Imaging (San Franc). November 1993;15(11):116-121. Publication Date November 1993 How Analyze was Used “A 3-D model of the transducer was also exported to Analye for superimposition to the temporal bone image.” Keywords Algorithms Cochlear Implants Ear Diseases/radiography Equipment Design Evaluation Studies as…