Tag Archives: Equipment Failure Analysis

A new metaphyseal bone defect model in osteoporotic rats to study biomaterials for the enhancement of bone healing in osteoporotic fractures

Alt V, Thormann U, Ray S, Zahner D, Dürselen L, Lips K, El Khassawna T, Heiss C, Riedrich A, Schlewitz G, Ignatius A, Kampschulte M, von Dewitz H, Heinemann S, Schnettler R, Langheinrich A. A new metaphyseal bone defect model in osteoporotic rats to study biomaterials for the enhancement of bone healing in osteoporotic fractures….

Mineralisation and mechanical strength of the glenoid cavity subchondral bone plate

Kraljević M, Zumstein V, Wirz D, Hügli R, Müller-Gerbl M. Mineralisation and mechanical strength of the glenoid cavity subchondral bone plate. Int Orthop. December 2011;35(12):1813-1819. Full Text – Open Access Publication Date December 2011 How Analyze was Used “Axial section thickness was set to 0.6 mm, and data were evaluated using the image analysing system…

The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene

Mall NA, Nunley RM, Zhu JJ, Maloney WJ, Barrack RL, Clohisy JC. The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene. Clin Orthop Relat Res. February 2011;469(2):372-381. Full Text – Open Access Publication Date February 2011 How Analyze was Used “Segmentation and volume calculations were performed using Analyze software (Version…

Minimally invasive holographic surface scanning for soft-tissue image registration

Lathrop RA, Hackworth DM, Webster RJ. Minimally invasive holographic surface scanning for soft-tissue image registration. IEEE Trans Biomed Eng. June 2010;57(6):1497-1506. Full Text – Open Access Publication Date June 2010 How Analyze was Used “Prior to testing, the liver phantom was scanned using the CT scanner with a voxel size of 0.729 mm × 0.729…

Incidence, anatomical location, and clinical significance of compressions and fractures in infrapopliteal balloon-expandable metal stents

Karnabatidis D, Katsanos K, Spiliopoulos S, Diamantopoulos A, Kagadis GC, Siablis D. Incidence, anatomical location, and clinical significance of compressions and fractures in infrapopliteal balloon-expandable metal stents. J Endovasc Ther. February 2009;16(1):15-22. Publication Date February 2009 How Analyze was Used “Digital images were then transferred to the Department of Medical Physics for processing using the…

Numerical investigations of stress shielding in total hip prostheses

Behrens BA, Wirth CJ, Windhagen H, Nolte I, Meyer-Lindenberg A, Bouguecha A. Numerical investigations of stress shielding in total hip prostheses. Proc Inst Mech Eng H. July 2008;222(5):593-600. Publication Date July 2008 How Analyze was Used “With the image analysis program Analyze …, three-dimensional surfaces of the image data were created in stereolithography format.” Keywords…

Performance of a novel piezoelectric motor at 4.7 T: applications and initial tests

Turowski SG, Seshadri M, Loecher M, Podniesinski E, Spernyak JA, Mazurchuk RV. Performance of a novel piezoelectric motor at 4.7 T: applications and initial tests. Magn Reson Imaging. April 2008;26(3):426-432. Publication Date April 2008 How Analyze was Used “Image processing and analysis of all raw data sets were carried out using commercially available software (ANALYZE…

Cone-beam x-ray microtomography of small specimens

Machin K, Webb S. Cone-beam x-ray microtomography of small specimens. Phys Med Biol. October 1994;39(10):1639-1657. Publication Date October 1994 How Analyze was Used “Images are displayed and manipulated using the ANALYZE … software package (Robb and Barillot 1989, Robb 1990).” Keywords Equipment Design Equipment Failure Analysis Imaging, Three-Dimensional/instrumentation/methods Phantoms, Imaging Radiographic Image Enhancement/instrumentation/methods Radiographic Image…