Tag Archives: Endoscopy/methods

CT virtual intravascular endoscopy assessment of coronary artery plaques: a preliminary study

Sun Z, Dimpudus FJ, Nugroho J, Adipranoto JD. CT virtual intravascular endoscopy assessment of coronary artery plaques: a preliminary study. Eur J Radiol. July 2010;75(1):e112-119. Publication Date July 2010 How Analyze was Used “Original DICOM data (digital imaging and communication in medicine) were transferred to a workstation equipped with Analyze V 7.0 (AnalyzeDirect, Inc., Lenexa,…

Multislice CT virtual intravascular endoscopy for assessing pulmonary embolisms: a pictorial review

Sun Z, Dosari SA, Ng C, al-Muntashari A, Almaliky S. Multislice CT virtual intravascular endoscopy for assessing pulmonary embolisms: a pictorial review. Korean J Radiol. March 2010;11(2):222-230. Full Text – Open Access Publication Date March 2010 How Analyze was Used “The MSCT volume data was converted from the original DICOM (Digital Imaging and Communication in…

Computed tomography virtual intravascular endoscopy in the evaluation of fenestrated stent graft repair of abdominal aortic aneurysms

Sun Z, Mwipatayi BP, Allen YB, Hartley DE, Lawrence-Brown MMD. Computed tomography virtual intravascular endoscopy in the evaluation of fenestrated stent graft repair of abdominal aortic aneurysms. ANZ J Surg. November 2009;79(11):836-840. Full Text – Open Access Publication Date November 2009 How Analyze was Used “Original digital imaging and communication in medicine data of pre…

Effect of suprarenal fixation of aortic stent-grafts on the renal artery ostia: assessment of morphological changes by virtual intravascular endoscopy

Sun Z, O’Donnell ME, Winder RJ, Ellis PK, Blair PH. Effect of suprarenal fixation of aortic stent-grafts on the renal artery ostia: assessment of morphological changes by virtual intravascular endoscopy. J Endovasc Ther. October 2007;14(5):650-660. Publication Date October 2007 How Analyze was Used “CT volume data were converted from original DICOM (Digital Imaging and Communication…

Optimal scanning protocol of multislice CT virtual intravascular endoscopy in pre-aortic stent grafting: in vitro phantom study

Sun Z, Ferris C. Optimal scanning protocol of multislice CT virtual intravascular endoscopy in pre-aortic stent grafting: in vitro phantom study. Eur J Radiol. May 2006;58(2):310-316. Publication Date May 2006 How Analyze was Used “CT data were burned into CDs and transferred to a workstation equipped with Analyze V 5.0 (https://analyzedirect.com/ …) for data processing.”…

Effect of suprarenal stent struts on the renal artery with ostial calcification observed on CT virtual intravascular endoscopy

Sun Z, Zheng H. Effect of suprarenal stent struts on the renal artery with ostial calcification observed on CT virtual intravascular endoscopy. Eur J Vasc Endovasc Surg. November 2004;28(5):534-542. Full Text – Open Access Publication Date November 2004 How Analyze was Used “Virtual endoscopic images of the renal ostium and aortic stent struts were post-processed…

Magnetic resonance imaging virtual endoscopy of the labyrinth

Diamantopoulos, II, Ludman CN, Martel AL, O’Donoghue GM. Magnetic resonance imaging virtual endoscopy of the labyrinth. Am J Otol. November 1999;20(6):748-751. Publication Date November 1999 How Analyze was Used “The MR images were transferred to an SGI Indigo-2 … workstation, and Analyze AVW software … was used for image postprocessing.” Keywords Algorithms Child, Preschool Ear,…

Evaluating virtual endoscopy for clinical use

Blezek DJ, Robb RA. Evaluating virtual endoscopy for clinical use. J Digit Imaging. August 1997;10(3 Suppl 1):51-55. Full Text – Open Access Publication Date August 1997 How Analyze was Used “Tumor response studies could be signifi- cantly augmented by virtual endoscopy, coupled with powerful analysis tools such as AnalyzeAVW.” Keywords Algorithms Anatomy, Cross-Sectional Bronchi/anatomy &…