Tag Archives: Computer-Assisted Surgery/methods

On mixed reality environments for minimally invasive therapy guidance: systems architecture, successes and challenges in their implementation from laboratory to clinic

Linte CA, Davenport KP, Cleary K, Peters C, Vosburgh KG, Navab N, Edwards PE, Jannin P, Peters TM, Holmes DR, 3rd, Robb RA. On mixed reality environments for minimally invasive therapy guidance: systems architecture, successes and challenges in their implementation from laboratory to clinic. Comput Med Imaging Graph. March 2013;37(2):83-97. Full Text – Open Access…

Does intraoperative navigation restore orbital dimensions in traumatic and post-ablative defects?

Markiewicz MR, Dierks EJ, Bell RB. Does intraoperative navigation restore orbital dimensions in traumatic and post-ablative defects? J Craniomaxillofac Surg. February 2012;40(2):142-148. Publication Date February 2012 How Analyze was Used “Pre- and post-operative orbital volume and globe projection were measured using Analyze.” Keywords Adolescent Adult Aged Cohort Studies Exophthalmos/surgery Female Humans Image Processing, Computer-Assisted Intraoperative…

An instantiability index for intra-operative tracking of 3D anatomy and interventional devices

Lee SL, Riga C, Crowie L, Hamady M, Cheshire N, Yang GZ. An instantiability index for intra-operative tracking of 3D anatomy and interventional devices. Med Image Comput Comput Assist Interv. October 2011;14(Pt 1):49-56. Publication Date October 2011 How Analyze was Used “Ten catheter positions were collected. Analyze (AnalyzeDirect, Inc, Overland Park, KS, USA) was used…

Intraoperative brain shift compensation: accounting for dural septa

Chen I, Coffey AM, Ding S, Dumpuri P, Dawant BM, Thompson RC, Miga MI. Intraoperative brain shift compensation: accounting for dural septa. IEEE Trans Biomed Eng. March 2011;58(3):499-508. Full Text – Open Access Publication Date March 2011 How Analyze was Used “Some segmentation and calculations were performed using Analyze AVW Version 9.0.” Keywords Adult Aged…

Dynamic shape instantiation for intra-operative guidance

Lee SL, Chung A, Lerotic M, Hawkins MA, Tait D, Yang GZ. Dynamic shape instantiation for intra-operative guidance. Med Image Comput Comput Assist Interv. September 2010;13(Pt 1):69-76. Publication Date September 2010 How Analyze was Used “Segmentation and 3D model building were performed in Analyze (AnalyzeDirect, Inc, Overland Park, KS, USA).” Keywords Algorithms Computer Simulation Female…

A fast and efficient method to compensate for brain shift for tumor resection therapies measured between preoperative and postoperative tomograms

Dumpuri P, Thompson RC, Cao A, Ding S, Garg I, Dawant BM, Miga MI. A fast and efficient method to compensate for brain shift for tumor resection therapies measured between preoperative and postoperative tomograms. IEEE Trans Biomed Eng. June 2010;57(6):1285-1296. Full Text – Open Access Publication Date June 2010 How Analyze was Used “Some segmentation…

3D computer-assisted assessment of complicated penetrating foreign bodies cases in ENT practice

Vaiman M, Bekerman I, Puterman M. 3D computer-assisted assessment of complicated penetrating foreign bodies cases in ENT practice. Eur Arch Otorhinolaryngol. October 2009;266(10):1599-1603. Publication Date October 2009 How Analyze was Used “3D imaging was performed in a way of surface rendering (3D Viewnix V1.1, Analyze AVW software).” Keywords Foreign Bodies/radiography/surgery Humans Image Processing, Computer-Assisted/methods Imaging,…

An event-driven distributed processing architecture for image-guided cardiac ablation therapy

Rettmann ME, Holmes DR, 3rd, Cameron BM, Robb RA. An event-driven distributed processing architecture for image-guided cardiac ablation therapy. Comput Methods Programs Biomed. August 2009;95(2):95-104. Full Text – Open Access Publication Date August 2009 How Analyze was Used “In order to construct the surface model, the left atrium and pulmonary veins are segmented from a…

A subject-specific technique for respiratory motion correction in image-guided cardiac catheterisation procedures

King AP, Boubertakh R, Rhode KS, Ma YL, Chinchapatnam P, Gao G, Tangcharoen T, Ginks M, Cooklin M, Gill JS, Hawkes DJ, Razavi RS, Schaeffter T. A subject-specific technique for respiratory motion correction in image-guided cardiac catheterisation procedures. Med Image Anal. June 2009;13(3):419-431. Publication Date June 2009 How Analyze was Used “For both patients and…

Feasibility study for image-guided kidney surgery: assessment of required intraoperative surface for accurate physical to image space registrations

Benincasa AB, Clements LW, Herrell SD, Galloway RL. Feasibility study for image-guided kidney surgery: assessment of required intraoperative surface for accurate physical to image space registrations. Med Phys. September 2008;35(9):4251-4261. Full Text – Open Access Publication Date September 2008 How Analyze was Used “Computed tomography (CT) images of both phantom orientations were acquired. The kidney…