Tag Archives: Computer-Assisted Radiographic Image Interpretation

Multislice CT angiography in the follow-up of fenestrated endovascular grafts: effect of slice thickness on 2D and 3D visualization of the fenestration stents

Sun Z, Allen YB, Mwipatayi BP, Hartley DE, Lawrence-Brown MMD. Multislice CT angiography in the follow-up of fenestrated endovascular grafts: effect of slice thickness on 2D and 3D visualization of the fenestration stents. J Endovasc Ther. August 2008;15(4):417-426. Publication Date August 2008 How Analyze was Used “Original DICOM (Digital Imaging and Communication in Medicine) data…

Measuring noncalcified coronary atherosclerotic plaque using voxel analysis with MDCT angiography: phantom validation

Sabir A, Yam CS, Yoshimura N, Buros JL, De Grand AM, Raptopoulos V, Clouse ME. Measuring noncalcified coronary atherosclerotic plaque using voxel analysis with MDCT angiography: phantom validation. AJR Am J Roentgenol. April 2008;190(4):W242-246. Full Text – Open Access Publication Date April 2008 How Analyze was Used “Cross-sectional images were reconstructed using 400-μ voxels on…

CT virtual intravascular endoscopy in the visualization of fenestrated stent-grafts

Sun Z, Allen YB, Nadkarni S, Knight R, Hartley DE, Lawrence-Brown MMD. CT virtual intravascular endoscopy in the visualization of fenestrated stent-grafts. J Endovasc Ther. February 2008;15(1):42-51. Publication Date February 2008 How Analyze was Used “All CT data were transferred to a workstation equipped with Analyze software (version 7.0; AnalyzeDirect, Inc., Lenexa, KS, USA) for…

Four-dimensional computed tomographic imaging in the wrist: proof of feasibility in a cadaveric model

Tay SC, Primak AN, Fletcher JG, Schmidt B, Amrami KK, Berger RA, McCollough CH. Four-dimensional computed tomographic imaging in the wrist: proof of feasibility in a cadaveric model. Skeletal Radiol. December 2007;36(12):1163-1169. Publication Date December 2007 How Analyze was Used “The DICOM CT data were imported into Analyze 7.0 … for image analysis.” Keywords Artifacts…

Effect of suprarenal fixation of aortic stent-grafts on the renal artery ostia: assessment of morphological changes by virtual intravascular endoscopy

Sun Z, O’Donnell ME, Winder RJ, Ellis PK, Blair PH. Effect of suprarenal fixation of aortic stent-grafts on the renal artery ostia: assessment of morphological changes by virtual intravascular endoscopy. J Endovasc Ther. October 2007;14(5):650-660. Publication Date October 2007 How Analyze was Used “CT volume data were converted from original DICOM (Digital Imaging and Communication…

Cone-beam x-ray microtomography of small specimens

Machin K, Webb S. Cone-beam x-ray microtomography of small specimens. Phys Med Biol. October 1994;39(10):1639-1657. Publication Date October 1994 How Analyze was Used “Images are displayed and manipulated using the ANALYZE … software package (Robb and Barillot 1989, Robb 1990).” Keywords Equipment Design Equipment Failure Analysis Imaging, Three-Dimensional/instrumentation/methods Phantoms, Imaging Radiographic Image Enhancement/instrumentation/methods Radiographic Image…