Tag Archives: Computer-Assisted Image Processing/methods

Cranial growth after distraction osteogenesis of the craniosynostosis

Kim YO, Choi JW, Kim DS, Lee WJ, Yoo SK, Kim HJ, Choi JE, Park B. Cranial growth after distraction osteogenesis of the craniosynostosis. J Craniofac Surg. January 2008;19(1):45-55. Publication Date January 2008 How Analyze was Used “Three-dimensional CT scans were reconstructed using Analyze AVW (version 5.0…) with 0.5 mm of voxel size.” Keywords Cephalometry…

Non-arteritic anterior ischaemic optic neuropathy: evaluation of the brain and optic pathway by conventional MRI and magnetisation transfer imaging

Argyropoulou MI, Zikou AK, Tzovara I, Nikas A, Blekas K, Margariti P, Galatsanos N, Asproudis I. Non-arteritic anterior ischaemic optic neuropathy: evaluation of the brain and optic pathway by conventional MRI and magnetisation transfer imaging. Eur Radiol. July 2007;17(7):1669-1674. Publication Date July 2007 How Analyze was Used “Area and volume of the retrobulbar optic nerve…

Rates of cerebral atrophy differ in different degenerative pathologies

Whitwell JL, Jack CR, Jr., Parisi JE, Knopman DS, Boeve BF, Petersen RC, Ferman TJ, Dickson DW, Josephs KA. Rates of cerebral atrophy differ in different degenerative pathologies. Brain. April 2007;130(Pt 4):1148-1158. Full Text – Open Access Publication Date April 2007 How Analyze was Used “Ventricular segmentations were performed on all repeat scans for each…

Comparison of manual tracing versus a semiautomatic radial measurement method in temporal lobe MRI volumetry for pharmacoresistant epilepsy

Müeller CA, Scorzin J, Koenig R, Urbach H, Fimmers R, Zentner J, Lehmann TN, Schramm J. Comparison of manual tracing versus a semiautomatic radial measurement method in temporal lobe MRI volumetry for pharmacoresistant epilepsy. Neuroradiology. March 2007;49(3):189-201. Publication Date March 2007 How Analyze was Used “All image processing steps and volume measurements were performed using…

Comparison of mathematic models for assessment of glomerular filtration rate with electron-beam CT in pigs

Daghini E, Juillard L, Haas JA, Krier JD, Romero JC, Lerman LO. Comparison of mathematic models for assessment of glomerular filtration rate with electron-beam CT in pigs. Radiology. February 2007;242(2):417-424. Full Text – Open Access Publication Date February 2007 How Analyze was Used “Reconstructed images were displayed on a workstation … with the Analyze ……

The craniofacial phenotype of the Crouzon mouse: analysis of a model for syndromic craniosynostosis using three-dimensional MicroCT

Perlyn CA, DeLeon VB, Babbs C, Govier D, Burell L, Darvann T, Kreiborg S, Morriss-Kay G. The craniofacial phenotype of the Crouzon mouse: analysis of a model for syndromic craniosynostosis using three-dimensional MicroCT. Cleft Palate Craniofac J. November 2006;43(6):740-748. Full Text – Open Access Publication Date November 2006 How Analyze was Used “We used ANALYZE…

Quantitative measurement and visual assessment of ileal Crohn’s disease activity by computed tomography enterography: correlation with endoscopic severity and C reactive protein

Colombel JF, Solem CA, Sandborn WJ, Booya F, Loftus EV, Jr., Harmsen WS, Zinsmeister AR, Bodily KD, Fletcher JG. Quantitative measurement and visual assessment of ileal Crohn’s disease activity by computed tomography enterography: correlation with endoscopic severity and C reactive protein. Gut. November 2006;55(11):1561-1567. Full Text – Open Access Publication Date November 2006 How Analyze…

Accuracy of three-dimensional measurements using cone-beam CT

Pinsky HM, Dyda S, Pinsky RW, Misch KA, Sarment DP. Accuracy of three-dimensional measurements using cone-beam CT. Dentomaxillofac Radiol. November 2006;35(6):410-416. Full Text – Open Access Publication Date November 2006 How Analyze was Used “Automated volume calculation: CBCT data were imported into a separate software (Analyze; AnalyzeDirect Inc.).” Keywords Acrylic Resins Humans Image Processing, Computer-Assisted/methods…

Medial temporal lobe volume of nondemented elderly individuals with poor cognitive functions

Chey J, Na DG, Tae WS, Ryoo JW, Hong SB. Medial temporal lobe volume of nondemented elderly individuals with poor cognitive functions. Neurobiol Aging. September 2006;27(9):1269-1279. Publication Date September 2006 How Analyze was Used “The preprocessing of SPGR MRI data and the measurement of brain volume were performed using Analyze 7.5 image software.” Keywords Age…

How affected is oxygen metabolism in DWI lesions?: a combined acute stroke PET-MR study

Guadagno JV, Warburton EA, Jones PS, Day DJ, Aigbirhio FI, Fryer TD, Harding S, Price CJ, Green HA, Barret O, Gillard JH, Baron JC. How affected is oxygen metabolism in DWI lesions?: a combined acute stroke PET-MR study. Neurology. September 2006;67(5):824-829. Publication Date September 2006 How Analyze was Used “Using ANALYZE 5.0 (AnalyzeDirect Inc., KS)…