Yoshii Y, Zhao C, Zhao KD, Zobitz ME, An KN, Amadio PC. The effect of wrist position on the relative motion of tendon, nerve, and subsynovial connective tissue within the carpal tunnel in a human cadaver model. J Orthop Res. August 2008;26(8):1153-1158. Full Text – Open Access Publication Date August 2008 How Analyze was Used…
Yamaguchi T, Osamura N, Zhao C, An KN, Amadio PC. Relative longitudinal motion of the finger flexors, subsynovial connective tissue, and median nerve before and after carpal tunnel release in a human cadaver model. J Hand Surg Am. July 2008;33(6):888-892. Full Text – Open Access Publication Date July 2008 How Analyze was Used “The data…
Greaves L, Gilbart M, Yung A, Kozlowski P, Wilson D. Cartilage deformation under load in a human cadaveric hip measured with 7.0 T qMRI. Paper presented at: ISMRM 16th Scientific Meeting and Exhibition; May 2008, Toronto. Publication Date May 2008 How Analyze was Used “For each time interval during deformation and recovery phases, the osseous…
Calfee RP, Leventhal EL, Wilkerson J, Moore DC, Akelman E, Crisco JJ. Simulated radioscapholunate fusion alters carpal kinematics while preserving dart-thrower’s motion. J Hand Surg Am. April 2008;33(4):503-510. Full Text – Open Access Publication Date April 2008 How Analyze was Used “Bony surfaces were generated from the high-resolution neutral-position CT scans using Analyze …, Geomagic…
Zhao L, Herman JE, Patel PK. The structural implications of a unilateral facial skeletal cleft: a three-dimensional finite element model approach. Cleft Palate Craniofac J. March 2008;45(2):121-130. Full Text – Open Access Publication Date March 2008 How Analyze was Used “Using ANALYZE AVW 4.0…, the CT scan data were reformatted and the voxels were resized…
Pfeifer R, Hurschler C, Ostermeier S, Windhagen H, Pressel T. In vitro investigation of biomechanical changes of the hip after Salter pelvic osteotomy. Clin Biomech (Bristol, Avon). March 2008;23(3):299-304. Publication Date March 2008 How Analyze was Used “Continuous 1.5 mm thick slices were used to create a three-dimensional surface reconstruction of the left hemipelvis and…
Tay SC, Tomita K, van Riet R, Amrami KK, An K-N, Berger RA. In-vivo kinematic analysis of the forearm. Paper presented at: The 2008 Annual Meeting: American Society for Peripheral Nerve, American Society for Reconstructive Microsurgery, The American Association for Hand Surgery, January 2008; Beverly Hills, CA, US. Publication Date January 2008 How Analyze was…
Lin CY, Wirtz T, LaMarca F, Hollister SJ. Structural and mechanical evaluations of a topology optimized titanium interbody fusion cage fabricated by selective laser melting process. J Biomed Mater Res A. November 2007;83(2):272-279. Publication Date November 2007 How Analyze was Used “The scanned features were also compared with the original design by registering corresponding 3-D…
Fransson BA, Zhu Q, Bagley RS, Tucker R, Oxland TR. Biomechanical evaluation of cervical intervertebral plug stabilization in an ovine model. Vet Surg. July 2007;36(5):449-457. Publication Date July 2007 How Analyze was Used “Each set of images were converted to a 3D volume file (Analyze™, … AnalyzeDirect, Lenexa, KS).” Keywords Animals Biomechanical Phenomena Decompression, Surgical/methods/veterinary…
Ettema AM, Zhao C, Amadio PC, O’Byrne MM, An KN. Gliding characteristics of flexor tendon and tenosynovium in carpal tunnel syndrome: a pilot study. Clin Anat. April 2007;20(3):292-299. Publication Date April 2007 How Analyze was Used “The data were digitized with the use of Analyze Software.” Keywords Aged Aged, 80 and over Biomechanical Phenomena Carpal…