Tag Archives: Articular Range of Motion/physiology

Transverse ultrasound assessment of median nerve deformation and displacement in the human carpal tunnel during wrist movements

Wang Y, Zhao C, Passe SM, Filius A, Thoreson AR, An KN, Amadio PC. Transverse ultrasound assessment of median nerve deformation and displacement in the human carpal tunnel during wrist movements. Ultrasound Med Biol. January 2014;40(1):53-61. Full Text – Open Access Publication Date January 2014 How Analyze was Used “Each subject was imaged while sitting…

In-vivo kinematic analysis of forearm rotation using helical axis analysis

Tay SC, van Riet R, Kazunari T, Amrami KK, An KN, Berger RA. In-vivo kinematic analysis of forearm rotation using helical axis analysis. Clin Biomech (Bristol, Avon). August 2010;25(7):655-659. Publication Date August 2010 How Analyze was Used “The Digital Imaging and Communications in Medicine (DICOM) CT image data was imported into Analyze 7.0 (Robb et…

Consistency of patellar spin, tilt and lateral translation side-to-side and over a 1 year period in healthy young males

Macintyre NJ, McKnight EKB, Day A, Wilson DR. Consistency of patellar spin, tilt and lateral translation side-to-side and over a 1 year period in healthy young males. J Biomech. October 2008;41(14):3094-3096. Publication Date October 2008 How Analyze was Used “Subject-specific three-dimensional geometric surface models of the distal femur, proximal tibia and patella were generated by…

Simulated radioscapholunate fusion alters carpal kinematics while preserving dart-thrower’s motion

Calfee RP, Leventhal EL, Wilkerson J, Moore DC, Akelman E, Crisco JJ. Simulated radioscapholunate fusion alters carpal kinematics while preserving dart-thrower’s motion. J Hand Surg Am. April 2008;33(4):503-510. Full Text – Open Access Publication Date April 2008 How Analyze was Used “Bony surfaces were generated from the high-resolution neutral-position CT scans using Analyze …, Geomagic…

Biomechanical evaluation of cervical intervertebral plug stabilization in an ovine model

Fransson BA, Zhu Q, Bagley RS, Tucker R, Oxland TR. Biomechanical evaluation of cervical intervertebral plug stabilization in an ovine model. Vet Surg. July 2007;36(5):449-457. Publication Date July 2007 How Analyze was Used “Each set of images were converted to a 3D volume file (Analyze™, … AnalyzeDirect, Lenexa, KS).” Keywords Animals Biomechanical Phenomena Decompression, Surgical/methods/veterinary…

In vivo elongation of the palmar and dorsal scapholunate interosseous ligament

Upal MA, Crisco JJ, Moore DC, Sonenblum SE, Wolfe SW. In vivo elongation of the palmar and dorsal scapholunate interosseous ligament. J Hand Surg Am. October 2006;31(8):1326-1332. Publication Date October 2006 How Analyze was Used “Slice-by-slice segmentation was performed using image-processing software (ANALYZE).” Keywords Adult Biomechanical Phenomena Carpal Joints/physiology/radiography Female Humans Imaging, Three-Dimensional Ligaments, Articular/physiology/radiography…

A kinematics-based method for generating cartilage maps and deformations in the multi-articulating wrist joint from CT images

Marai GE, Crisco JJ, Laidlaw DH. A kinematics-based method for generating cartilage maps and deformations in the multi-articulating wrist joint from CT images. Conf Proc IEEE Eng Med Biol Soc. August 2006;1:2079-2082. Full Text – Open Access Publication Date August 2006 How Analyze was Used “The μCT volume image was imported into Analyze image analysis…

Three-dimensional reconstruction of TMJ MR images: a technical note and case report

Kitai N, Eriksson L, Kreiborg S, Wagner A, Takada K. Three-dimensional reconstruction of TMJ MR images: a technical note and case report. Cranio. January 2004;22(1):77-81. Publication Date January 2004 How Analyze was Used “Four data sets (occlusion, 1, 2 and 3 cm between the incisors) for the left joint were registered three-dimensionally according to the…