Tag Archives: Angiography

The relation between de novo atherosclerosis remodeling and angioplasty-induced remodeling in an atherosclerotic Yucatan micropig model

de Smet BJGL, Pasterkamp G, van der Helm YJ, Borst C, Post MJ. The relation between de novo atherosclerosis remodeling and angioplasty-induced remodeling in an atherosclerotic Yucatan micropig model. Arterioscler Thromb Vasc Biol. May 1998;18(5):702-707. Full Text – Open Access Publication Date May 1998 How Analyze was Used “The frames were digitized using a videograbber…

Accurate and efficient image intensifier distortion correction algorithm for volume tomographic angiography

Wang X, Ning R. Accurate and efficient image intensifier distortion correction algorithm for volume tomographic angiography. Opt Eng. March 1998;37(3):977-983. Publication Date March 1998 How Analyze was Used “The image cube 5123 8-bit was processed by the software ANALYZE.” Keywords Algorithms Angiography Calibration Phantoms, Imaging Radiographic Image Enhancement Tomography, X-Ray Computed (CT) Author Affiliation(s) University…

Arterial remodeling after balloon angioplasty or stenting in an atherosclerotic experimental model

Post MJ, de Smet BJGL, van der Helm Y, Borst C, Kuntz RE. Arterial remodeling after balloon angioplasty or stenting in an atherosclerotic experimental model. Circulation. August 1997;96(3):996-1003. Full Text – Open Access Publication Date August 1997 How Analyze was Used “For morphometry, the EvG-stained sections were used. Images of the sections were recorded, digitized,…

Accurate and efficient image-intensifier distortion-correction algorithm and its application in volume tomographic angiography

Wang X, Ning R. Accurate and efficient image-intensifier distortion-correction algorithm and its application in volume tomographic angiography. Paper presented at: Medical Imaging 1997: Physics of Medical Imaging, February 1997; Newport Beach, CA, US. Publication Date February 1997 How Analyze was Used “The 3D display of the reconstructed vascular phantom is shown in Fig. 7. The…

Three-dimensional CT subtraction angiography

ter Haar Romeny BM, Bastin FH, Steenbeek J, Zuiderveld KJ, Viergever MA. Three-dimensional CT subtraction angiography. Paper presented at: Visualization in Biomedical Computing 1994; October 1994, Rochester, MN, US. Publication Date October 1994 How Analyze was Used “For relatively stable objects, like human heads, global rigid transformations are sufficient … The actual matching procedure is…