Tag Archives: Algorithms

Automatic extraction of endocranial surfaces from CT images of crania

Takashi Michikawa, Hiromasa Suzuki, Masaki Moriguchi, Naomichi Ogihara, Osamu Kondo, Yasushi Kobayashi. Automatic extraction of endocranial surfaces from CT images of crania. PLOS One. April 13, 2017. Full Text – Open Access Publication Date April 2017 How Analyze was Used “The results shown in Fig 8A was created using medical imaging software, Analyze 9.0” Keywords…

Extrafrontal structural changes in juvenile myoclonic epilepsy: a topographic analysis of combined structural and microstructural brain imaging

Kim SH, Lim S-C, Kim W, Kwon O-h, Jeon S, Lee J-M, Shon Y-M. Extrafrontal structural changes in juvenile myoclonic epilepsy: a topographic analysis of combined structural and microstructural brain imaging. Seizure. August 2015;30(0):124-131. Publication Date August 2015 How Analyze was Used “A single expert (JH Cho) blinded to all identities and characteristics of the…

Theoretical optimization of stimulation strategies for a directionally segmented deep brain stimulation electrode array

Xiao Y, Pena E, Johnson M. Theoretical optimization of stimulation strategies for a directionally segmented deep brain stimulation electrode array. IEEE Trans Biomed Eng. July 2015. Publication Date July 2015 How Analyze was Used “SWI data was aligned to the anterior commissure (AC)-posterior commissure (PC) plane (Analyze 11.0, AnalyzeDirect) and resliced into serial coronal sections…

Feasibility of radiation dose reduction using AIDR-3D in dynamic pulmonary CT perfusion

Mirsadraee S, Weir NW, Connolly S, Murchison JT, Reid JH, Hirani N, Connell M, van Beek EJ. Feasibility of radiation dose reduction using AIDR-3D in dynamic pulmonary CT perfusion. Clin Radiol. May 2015. Publication Date May 2015 How Analyze was Used “Analyze software (AnalyzeDirect, [Overland Park], KS, USA) was used to define and store identical…

Factors affecting dimensional accuracy of 3-D printed anatomical structures derived from CT data

Ogden KM, Aslan C, Ordway N, Diallo D, Tillapaugh-Fay G, Soman P. Factors affecting dimensional accuracy of 3-D printed anatomical structures derived from CT data. J Digit Imaging. May 2015:1-10. Publication Date May 2015 How Analyze was Used “As described in the prior work, the CT data from the L1 vertebra was processed in Analyze…

Loss of phosphodiesterase 10A signalling is associated with progression and severity in patients with Parkinson’s disease

Niccolini F, Foltynie T, Reis Marques T, Searle G, Natesan S, Kapur S, Rabiner E, Gunn R, Piccini P, Politis M. Loss of phosphodiesterase 10A signalling is associated with progression and severity in patients with Parkinson’s disease. Abstract. J Nucl Med. May 2015;56(supplement 3):31. Full Text – Open Access Publication Date May 2015 How Analyze…

Visualization and segmentation of reciprocal cerebrocerebellar pathways in the healthy and injured brain

Law N, Greenberg M, Bouffet E, Laughlin S, Taylor MD, Malkin D, Liu F, Moxon-Emre I, Scantlebury N, Skocic J, Mabbott D. Visualization and segmentation of reciprocal cerebrocerebellar pathways in the healthy and injured brain. Hum Brain Mapp. April 2015. Publication Date April 2015 How Analyze was Used “The 10 sets of individually-delineated ROIs (11…

Semiautomatic segmentation and follow-up of multicomponent low-grade tumors in longitudinal brain MRI studies

Weizman L, Sira LB, Joskowicz L, Rubin DL, Yeom KW, Constantini S, Shofty B, Bashat DB. Semiautomatic segmentation and follow-up of multicomponent low-grade tumors in longitudinal brain MRI studies. Med Phys. May 2014;41(5):052303. Publication Date May 2014 How Analyze was Used “One radiologist from each institution manually produced segmentations for the scans acquired at his/her…

Circulating inflammatory markers are associated with magnetic resonance imaging-visible perivascular spaces but not directly with white matter hyperintensities

Aribisala BS, Wiseman S, Morris Z, Valdes-Hernandez MC, Royle NA, Maniega SM, Gow AJ, Corley J, Bastin ME, Starr J, Deary IJ, Wardlaw JM. Circulating inflammatory markers are associated with magnetic resonance imaging-visible perivascular spaces but not directly with white matter hyperintensities. Stroke. February 2014;45(2):605-607. Full Text – Open Access Publication Date February 2014 How…

Electric source imaging of interictal activity accurately localises the seizure onset zone

Mégevand P, Spinelli L, Genetti M, Brodbeck V, Momjian S, Schaller K, Michel CM, Vulliemoz S, Seeck M. Electric source imaging of interictal activity accurately localises the seizure onset zone. J Neurol Neurosurg Psychiatry. January 2014;85(1):38-43. Publication Date January 2014 How Analyze was Used “Intracranial electrodes were localised on a postimplantation CT scan and coregistered…