Nofzinger EA, Buysse DJ, Miewald JM, Meltzer CC, Price JC, Sembrat RC, Ombao H, Reynolds CF, Monk TH, Hall M, Kupfer DJ, Moore RY. Human regional cerebral glucose metabolism during non-rapid eye movement sleep in relation to waking. Brain. May 2002;125(Pt 5):1105-1115. Full Text – Open Access Publication Date May 2002 How Analyze was Used…
Frodl T, Meisenzahl E, Zetzsche T, Bottlender R, Born C, Groll C, Jäger M, Leinsinger G, Hahn K, Möller HJ. Enlargement of the amygdala in patients with a first episode of major depression. Biol Psychiatry. May 2002;51(9):708-714. Publication Date May 2002 How Analyze was Used “For further image processing with size reduction from 16 to…
Shah PJ, Glabus MF, Goodwin GM, Ebmeier KP. Chronic, treatment-resistant depression and right fronto-striatal atrophy. Br J Psychiatry. May 2002;180:434-440. Full Text – Open Access Publication Date May 2002 How Analyze was Used “Image analysis was performed on a SPARC workstation … using ANALYZE software (version 7.5.5).” Keywords Adult Aged Atrophy/psychology Brain/pathology/physiopathology Brain Mapping Chronic…
Traxler H, Ender HG, Weber G, Surd R, Redl H, Firbas W. Applying circular posterior-hinged craniotomy to malignant cerebral edemas. Clin Anat. May 2002;15(3):173-181. Publication Date May 2002 How Analyze was Used “The slices were processed with the software package ANALYZE-AVW 1.1 to create virtual endocasts by tracing the inner boundaries of the skulls and…
Murphy MA, O’Brien TJ, Cook MJ. Insertion of depth electrodes with or without subdural grids using frameless stereotactic guidance systems–technique and outcome. Br J Neurosurg. April 2002;16(2):119-125. Publication Date April 2002 How Analyze was Used “Post-acquisition processing and registration … was performed with the aid of commercial image analysis software packages (ANALYZETM 7.5 and Analyze/AVW).”…
Stamatakis EA, Wilson JTL, Hadley DM, Wyper DJ. SPECT imaging in head injury interpreted with statistical parametric mapping. J Nucl Med. April 2002;43(4):476-483. Full Text – Open Access Publication Date April 2002 How Analyze was Used “The SPM result showing blood flow deficits for each patient was converted to a black-and-white Analyze … image (white…
Kaiboriboon K, Lowe VJ, Chantarujikapong SI, Hogan RE. The usefulness of subtraction ictal SPECT coregistered to MRI in single- and dual-headed SPECT cameras in partial epilepsy. Epilepsia. April 2002;43(4):408-414. Full Text – Open Access Publication Date April 2002 How Analyze was Used “Using the technique reported by O’Brien et al. [1998], the SISCOM images were…
Jones DK, Williams SCR, Gasston D, Horsfield MA, Simmons A, Howard R. Isotropic resolution diffusion tensor imaging with whole brain acquisition in a clinically acceptable time. Hum Brain Mapp. April 2002;15(4):216-230. Publication Date April 2002 How Analyze was Used “The image processing package, Analyze …, was then used to reformat the data into coronal and…
Commean PK, Mueller MJ, Smith KE, Hastings M, Klaesner J, Pilgram T, Robertson DD. Reliability and validity of combined imaging and pressures assessment methods for diabetic feet. Arch Phys Med Rehabil. April 2002;83(4):497-505. Full Text – Open Access Publication Date April 2002 How Analyze was Used “The DICOM-formatted volumetric SXCT data was imported into the…
Moore DC, Hogan KA, Crisco JJ, 3rd, Akelman E, Dasilva MF, Weiss AP. Three-dimensional in vivo kinematics of the distal radioulnar joint in malunited distal radius fractures. J Hand Surg Am. March 2002;27(2):233-242. Publication Date March 2002 How Analyze was Used “The bones first were segmented from the CT images using ANALYZE software … and…